LBM study of natural convection heat transfer from a porous cylinder in an enclosure

期刊

出版社

SPRINGER
DOI: 10.1007/s00162-022-00632-z

关键词

Porous cylinder; Enclosure; Darcy number; Natural convection; Lattice Boltzmann method

资金

  1. Science and Engineering Research Board (SERB), a statutory body of Department of Science & Technology (DST), Government of India [MTR/2019/001440]

向作者/读者索取更多资源

This study investigates natural convection heat transfer from a porous cylinder placed at various positions in a square, cooled enclosure with air as the working fluid. Through numerical analysis, it is determined that the amount of heat transported from the heated porous cylinder is influenced by the Rayleigh number, Darcy number, and the cylinder's location. The results show that convective effects are more noticeable when the cylinder is positioned towards the enclosure's bottom wall.
Natural convection heat transfer from a porous cylinder put at various positions in a square, cooled enclosure, with air as the working fluid, is investigated in this work. The following setups are taken into account: The hot cylinder is placed in the middle of the enclosure, near the bottom, top, right sides, along diagonal as top-diagonal and bottom-diagonal. The cylinder and the enclosure walls are kept hot and cold, respectively. The lattice Boltzmann method is used to perform a numerical analysis for Rayleigh number 10(4) <= Ra <= 10(6) and Darcy number 10(-6) <= Da <= 10(-2). The results are plotted as streamlines, isotherms, and local and mean Nusselt number values. The amount of heat transported from the heated porous cylinder is determined by varying Ra, Da, and the cylinder location. Even at a lower Rayleigh number (10(4)), the average Nusselt number grows by nearly 70 % as the cylinder moves from the centre to the bottom and 105% as it moves to bottom-diagonal location when Da = 10(-2). At Ra = 10(6) and Da = 10(-2), the heat transfer rate of the cylinder located near the corner of the enclosure at the bottom wall increases by approximately 33% when compared to the case of the cylinder in the centre. Convective effects are more noticeable when the cylinder is positioned towards the enclosure's bottom wall. This research is applicable to electronic cooling applications in which a collection of electronic components is arranged in a circular pattern inside a cabinet.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据