期刊
TALANTA
卷 255, 期 -, 页码 -出版社
ELSEVIER
DOI: 10.1016/j.talanta.2022.123902
关键词
Trivalent chromium; Hexavalent chromium; Direct immersion dual-drop microextraction; Graphite furnace atomic absorption; spectrometry; Water samples
A novel method called direct immersion dual-drop microextraction (DIDDME) was developed for the separation and preconcentration of inorganic chromium species (Cr(III) and Cr(VI)) followed by graphite furnace atomic absorption spectrometry detection. The method involved immersing two organic drops into a stirred sample solution, with each drop containing a chelating reagent that reacts with a specific species. This method avoids tedious pre-treatment steps and showed satisfactory results in the analysis of environmental water samples and certified reference materials.
In this study, for the first time, a novel separation and preconcentration method of direct immersion dual-drop microextraction (DIDDME) was proposed for the species of inorganic chromium (Cr(III) and Cr(VI)) followed by graphite furnace atomic absorption spectrometry detection. The methodology is based on that two organic drops hold on the needle tips of microsyringes were concurrently immersed in a stirred sample solution. Each drop contains a chelating reagent, which can react with a specific species under the same pH value. Therefore, Cr(III) and Cr(VI) can be selectively extracted into different drops. This procedure did not require tedious and complicated pre-oxidation/pre-reduction and centrifugation/filtration operations, which may lead to the risk of sample contamination and analysis errors. Main parameters influencing separation, preconcentration and identification of the target species were investigated. An enrichment factor of 400-fold was obtained for Cr(III) and Cr(VI). Under the optimized conditions, detection limits for this method were 1.1 ng L-1 and 1.4 ng L-1 for Cr(III) and Cr(VI) with relative standard deviations of 5.1 and 6.3%, respectively. This procedure was applied for the separation, preconcentration and determination of Cr(III) and Cr(VI) in environmental water samples and certified reference materials with satisfactory results. Recoveries of spiked experiments ranged from 86.0 to 112%.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据