4.5 Article

Potential of enhancing a natural convection loop with a thermomagnetically pumped ferrofluid

期刊

JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS
卷 417, 期 -, 页码 148-159

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jmmm.2016.05.029

关键词

Heat transfer; Ferrofluid; Thermomagnetic pump; Fluid mechanics; Natural convection

资金

  1. Blue Sky Instrument of SINTEF Energy research through a Strategic Institute Programme (SIP) by the National Basic Funding Scheme of Norway

向作者/读者索取更多资源

The feasibility of using a thermomagnetically pumped ferrofluid to enhance the performance of a natural convection cooling loop is investigated. First, a simplified analytical estimate for the thermomagnetic pumping action is derived, and then design rules for optimal solenoid and ferrofluid are presented. The design rules are used to set up a medium-scale (1 m, 10-1000 W) case study, which is modeled using a previously published and validated model (Aursand et al. [1]). The results show that the thermomagnetic driving force is significant compared to the natural convection driving force, and may in some cases greatly surpass it. The results also indicate that cooling performance can be increased by factors up to 4 and 2 in the single-phase and two-phase regimes, respectively, even when taking into the account the added heat from the solenoid. The performance increases can alternatively be used to obtain a reduction in heat-sink size by up to 75%. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据