Comparison of the usability of an automatic sleep staging program via portable 1-channel electroencephalograph and manual sleep staging with traditional polysomnography

期刊

SLEEP AND BIOLOGICAL RHYTHMS
卷 21, 期 1, 页码 85-95

出版社

SPRINGER JAPAN KK
DOI: 10.1007/s41105-022-00421-5

关键词

Sleep structure; Neurophysiology; Medical economy; Clinical measurement; Measurement equipment; Diagnostic marker

向作者/读者索取更多资源

This study investigated the feasibility of an automated sleep stage scoring system called Sleep Scope and compared it with the traditional polysomnography scoring method. The results showed that despite some biases, there was sufficient concordance between Sleep Scope and polysomnography, indicating that this automated staging system could serve as a novel clinical tool for reducing the time and expenses required of medical staff and patients.
Automatic algorithms are a proposed alternative to manual assessment of polysomnography data for analyzing sleep structure; however, none are acceptably accurate for clinical use. We investigated the feasibility of an automated sleep stage scoring system called Sleep Scope, which is intended for use with portable 1-channel electroencephalograph, and compared it with the traditional polysomnography scoring method. Twenty-six outpatients and fourteen healthy volunteers underwent Sleep Scope and polysomnography assessments simultaneously. Polysomnography records were manually scored by three sleep experts. Sleep Scope records were scored using a dedicated auto-staging algorithm. Sleep parameters, including total sleep time, sleep latency, wake after sleep onset, and sleep efficiency, were calculated. The epoch-by-epoch pairwise concordance based on the classification of sleep into five stages (i.e., wake, rapid eye movement, N1, N2, and N3) was also evaluated after validating homogeneity and bias between Sleep Scope and polysomnography. Compared with polysomnography, Sleep Scope seemed to overestimate sleep latency by approximately 3 min, but there was no consistent tendency in bias in other sleep parameters. The Kappa values ranged from 0.66 to 0.75 for experts' inter-rater polysomnography scores and from 0.62 to 0.67 for Sleep Scope versus polysomnography scores, which indicated sufficient agreement in the determination of sleep stages based on the Landis and Koch criteria. We observed sufficient concordance between Sleep Scope and polysomnography despite lower concordance in sleep disorder patients. Thus, this auto-staging system might serve as a novel clinical tool for reducing the time and expenses required of medical staff and patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据