4.7 Article

Breath analyzer for personalized monitoring of exercise-induced metabolic fat burning

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 369, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.132192

关键词

Breath analyzer; Low-power chemiresistive sensor; Sensor array; Physical exercise; Metabolic fat burning monitoring; Recurrent neural network

资金

  1. National Research Foundation of Korea [NRF-2017M3A9F1033056, NRF-2021M3H4A4079271]
  2. National Research Foundation of Korea [2021M3H4A4079271] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Obesity increases the risk of chronic diseases, and it is important to develop portable devices to monitor exercise-induced fat burn in real time for weight management. In this study, a compact breath analyzer was developed for convenient and noninvasive estimation of fat burning, which showed a high level of accuracy using a machine learning algorithm.
Obesity increases the risk of chronic diseases, such as type 2 diabetes mellitus, dyslipidemia, and cardiovascular diseases. Simple anthropometric measurements have time limitations in reflecting short-term weight and body fat changes. Thus, for detecting, losing or maintaining weight in short term, it is desirable to develop portable/ compact devices to monitor exercise-induced fat burn in real time. Exhaled breath acetone and blood-borne beta-hydroxybutyric acid (BOHB) are both correlated biomarkers of the metabolic fat burning process that takes place in the liver, predominantly post-exercise. Here, we have fabricated a compact breath analyzer for convenient, noninvasive and personalized estimation of fat burning in real time in a highly automated manner. The analyzer collects end-tidal breath in a standardized, user-friendly manner and it is equipped with an array of four low-power MEMS sensors for enhanced accuracy; this device presents a combination of required and desirable design features in modern portable/compact breath analyzers. We analyzed the exhaled breath (with our analyzer) and the blood samples (for BOHB) in 20 participants after exercise; we estimated the values of BOHB, as indication of the fat burn, resulting in Pearson coefficient r between the actual and predicted BOHB of 0.8. The estimation uses the responses from the sensor array in our analyzer and demographic and anthropometric information from the participants as inputs to a machine learning algorithm. The system and approach herein may help guide regular exercise for weight loss and its maintenance based on individuals' own metabolic changes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据