4.7 Article

Accurate profiling of blood components in microliter with position-insensitive coplanar electrodes-based cytometry

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 367, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2022.132068

关键词

Position-insensitive single-cell impedance; measurement; Label-free 3-part leukocyte classification; Cell granularity characterization; Microfluidic impedance cytometry

资金

  1. Ministry of Education, Singapore [MOE-T2EP30120-0017]
  2. Changi General Hospital and Singapore University of Technology and Design, under the HealthTech Innovation Fund [CGH-SUTD-HTIF-2019-003]
  3. Natural Science Foundation of China [11904117]
  4. Jiangsu Government Scholarship

向作者/读者索取更多资源

This article proposes a microfluidic high-throughput impedance cytometry using a unique coplanar electrode configuration, which eliminates height-dependent sensitivity variation and enables accurate electrical cell profiling. The proposed technology can accurately classify and quantify both leukocytes and erythrocytes, offering red blood cell indices for diagnosis.
Differentiating and counting blood cell subtypes are essential for medical diagnosis. Microfluidic impedancebased cytometry has been discussed in the past decade as cost-effective and label-free cell classification using multi-cellular electrical properties. The coplanar electrode configuration is particularly desirable since it can dramatically reduce the device fabrication complexity and cost. However, very few research demonstrated accurate leukocyte classification with coplanar electrodes due to the in-channel height-dependent sensitivity variation in cell profiling caused by nonuniform electric field. Herein we propose a microfluidic high-throughput (up to 1000 cells/second) impedance cytometry with a unique coplanar electrode configuration to eliminate height-dependent sensitivity variation for accurate electrical cell profiling. The proposed position-insensitive cytometry enables an accurate 3-part leukocyte classification and quantification comparable with fluorescence-based cytometry. In addition, unlike conventional leukocyte classification approaches that require red blood cell lysis to remove noises caused by erythrocytes, the position-insensitive cytometry can distinguish erythrocytes simply based on cell sizes and characterize the mean size and distribution width of erythrocytes with leukocyte classification simultaneously, offering red blood cell indices for diagnosis with reduced test time. The position-insensitive impedance cytometry has the great potential to provide a point-of-care blood analysis for clinical utility in many diseases (i.e., infections, cancers and HIV).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据