4.7 Article

Optimization of Two-Compartment-Exchange- Model Analysis for Dynamic Contrast-Enhanced MRI Incorporating Bolus Arrival Time

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 45, 期 1, 页码 237-249

出版社

WILEY
DOI: 10.1002/jmri.25362

关键词

-

资金

  1. Yitzhak and Chaya Weinstein Research Institute for Signal Processing

向作者/读者索取更多资源

Purpose: To optimize the analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) under the two-compartment-exchange-model (2CXM) and to incorporate voxelwise bolus-arrival-time (BAT). Materials and Methods: The accuracy of the pharmacokinetic (PK) parameters, extracted from 3T DCE-MRI using 2CXM, was tested under several conditions: eight algorithms for data estimation; correction for BAT; using model selection; different temporal resolution and scan duration. Comparisons were performed on simulated data. The best algorithm was applied to seven patients with brain tumors or following stroke. The extracted perfusion parameters were compared to those of dynamic susceptibility contrast MRI (DSC-MRI). Results: ACoPeD (AIF-corrected-perfusion-DCE-MRI), an analysis using a 2nd derivative regularized-spline and incorporating BAT, achieved the most accurate estimation in simulated data, mean-relative-error: F-p, F, v(p), v(e): 24.8%, 41.7%, 26.4%, 27.2% vs. 76.5%, 190.8%, 78.8%, 82.39% of the direct four parameters estimation (one-sided two-sample t-test, P < 0.001). Correction for BAT increased the estimation accuracy of the PK parameters by more than 30% and provided a supertemporal resolution estimation of the BAT (higher than the acquired resolution, mean-absolute-error 0.2 sec). High temporal resolution (similar to 2 sec) is required to avoid biased estimation of PK parameters, and long scan duration (similar to 20 min) is important for reliable permeability but not for perfusion estimations, mean-error-reduction: E: similar to 12%, v(e): similar to 6%. Using ACoPeD, PK values from normal-appearing white matter, gray matter, and lesion were extracted from patients. Preliminary results showed significant voxelwise correlations to DSC-MRI, between flow values in a patient following stroke (r= 0.49, P < 0.001), and blood volume in a patient with a brain tumor (r= 0.62, P < 0.001). Conclusion: This study proposes an optimized analysis method, ACoPeD, for tissue perfusion and permeability estimation using DCE-MRI, to be used in clinical settings.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据