4.7 Article

Quantitative DWI implemented after DCE-MRI yields increased specificity for BI-RADS 3 and 4 breast lesions

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 44, 期 6, 页码 1642-1649

出版社

WILEY-BLACKWELL
DOI: 10.1002/jmri.25331

关键词

diffusion weighted MRI; breast; cancer; diagnostic techniques and procedures

向作者/读者索取更多资源

PurposeTo assess if specificity can be increased when semiautomated breast lesion analysis of quantitative diffusion-weighted imaging (DWI) is implemented after dynamic contrast-enhanced (DCE-) magnetic resonance imaging (MRI) in the workup of BI-RADS 3 and 4 breast lesions larger than 1cm. Materials and MethodsIn all, 120 consecutive patients (mean-age, 48 years; age range, 23-75 years) with 139 breast lesions (1cm) were examined (2010-2014) with 1.5T DCE-MRI and DWI (b=0, 50, 200, 500, 800, 1000 s/mm(2)) and the BI-RADS classification and histopathology were obtained. For each lesion malignancy was excluded using voxelwise semiautomated breast lesion analysis based on previously defined thresholds for the apparent diffusion coefficient (ADC) and the three intravoxel incoherent motion (IVIM) parameters: molecular diffusion (D-slow), microperfusion (D-fast), and the fraction of D-fast (f(fast)). The sensitivity (Se), specificity (Sp), and negative predictive value (NPV) based on only IVIM parameters combined in parallel (D-slow, D-fast, and f(fast)), or the ADC or the BI-RADS classification by DCE-MRI were compared. Subsequently, the Se, Sp, and NPV of the combination of the BI-RADS classification by DCE-MRI followed by the IVIM parameters in parallel (or the ADC) were compared. ResultsIn all, 23 of 139 breast lesions were benign. Se and Sp of DCE-MRI was 100% and 30.4% (NPV=100%). Se and Sp of IVIM parameters in parallel were 92.2% and 52.2% (NPV=57.1%) and for the ADC 95.7% and 17.4%, respectively (NPV=44.4%). In all, 26 of 139 lesions were classified as BI-RADS 3 (n=7) or BI-RADS 4 (n=19). DCE-MRI combined with ADC (Se=99.1%, Sp=34.8%) or IVIM (Se=99.1%, Sp=56.5%) did significantly improve (P=0.016) Sp of DCE-MRI alone for workup of BI-RADS 3 and 4 lesions (NPV=92.9%). ConclusionQuantitative DWI has a lower NPV compared to DCE-MRI for evaluation of breast lesions and may therefore not be able to replace DCE-MRI; when implemented after DCE-MRI as problem solver for BI-RADS 3 and 4 lesions, the combined specificity improves significantly. J. Magn. Reson. Imaging 2016;44:1642-1649.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据