4.5 Article

Artificial placenta technology: History, potential and perception

期刊

PLACENTA
卷 141, 期 -, 页码 10-17

出版社

W B SAUNDERS CO LTD
DOI: 10.1016/j.placenta.2022.10.003

关键词

[KEYWORDS]; Extremely preterm infant; Artificial placenta; Life support

向作者/读者索取更多资源

The artificial placenta is an experimental life support platform for extremely preterm infants. It provides oxygenation to the fetus and keeps the lung fluid-filled. With advancements in neonatal and obstetric care, the threshold for adopting this therapy has changed. The paper reviews the developmental history of the artificial placenta and provides an assessment of the field. Misrepresentations regarding its potential application are addressed.
As presently conceptualised, the artificial placenta (AP) is an experimental life support platform for extremely preterm infants (i.e. 400-600 g; 21-23+6 weeks of gestation) born at the border of viability. It is based around the oxygenation of the periviable fetus using gas-exchangers connected to the fetal vasculature. In this system, the lung remains fluid-filled and the fetus remains in a quiescent state. The AP has been in development for some sixty years. Over this time, animal experimental models have evolved iteratively from employing external pumpdriven systems used to support comparatively mature fetuses (generally goats or sheep) to platforms driven by the fetal heart and used successfully to maintain extremely premature fetuses weighing around 600 g. Simultaneously, sizable advances in neonatal and obstetric care mean that the nature of a potential candidate patient for this therapy, and thus the threshold success level for justifying its adoption, have both changed markedly since this approach was first conceived.Five landmark breakthroughs have occurred over the developmental history of the AP: i) the first human studies reported in the 1950's; ii) foundation animal studies reported in the 1960's; iii) the first extended use of AP technology combined with fetal pulmonary resuscitation reported in the 1990s; iv) the development of AP systems powered by the fetal heart reported in the 2000's; and v) the adaption of this technology to maintain extremely preterm fetuses (i.e. 500-600 g body weight) reported in the 2010's. Using this framework, the present paper will provide a review of the developmental history of this long-running experimental system and uptodate assessment of the published field today.With the apparent acceleration of AP technology towards clinical application, there has been an increase in the attention paid to the field, along with some inaccurate commentary regarding its potential application and merits. Additionally, this paper will address several misrepresentations regarding the potential application of AP technology that serve to distract from the significant potential of this approach to greatly improve outcomes for extremely preterm infants born at or close to the present border of viability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据