Dose perturbations in proton pencil beam delivery investigated by dynamically deforming silicone-based radiochromic dosimeters

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Time structure of pencil beam scanning proton FLASH beams measured with scintillator detectors and compared with log files

Eleni Kanouta et al.

Summary: A fast scintillator detector system was developed to measure the spot and transition duration in FLASH treatments. The detector system was tested in both phantom and in vivo experiments, showing good agreement with log files and demonstrating its feasibility for preclinical studies.

MEDICAL PHYSICS (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

AAPM Task Group Report 290: Respiratory motion management for particle therapy

Heng Li et al.

Summary: Respiratory motion-induced dose uncertainty is a significant concern in the treatment of thoracic and abdominal lesions using particle beams. This report reviews the impact of tumor motion and dosimetric considerations in particle radiotherapy, discusses current motion-management techniques and limitations, and provides guidance for quality assurance of motion-management procedures.

MEDICAL PHYSICS (2022)

Review Oncology

Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future

Julia M. Pakela et al.

Summary: The major aim of radiation therapy is to provide curative or palliative treatment to cancerous malignancies while minimizing damage to healthy tissues. Charged particle radiotherapy utilizing carbon ions or protons is uniquely suited for this task due to its ability to achieve highly conformal dose distributions around the tumor volume. Various strategies have been developed and implemented to monitor and correct for patient motion, but more work remains. Emerging technologies such as particle-based radiography imaging, tumor tracking and FLASH, and artificial intelligence show potential for improving motion mitigation in charged particle therapy.

FRONTIERS IN ONCOLOGY (2022)

Article Biology

Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction

Takahiro Yamada et al.

Summary: The study aims to evaluate the reliability of dose distributions for liver tumors treated with real-time-image gated SSPT (RGPT). Results show that the accumulated dose distributions demonstrate a high level of accuracy, with average differences in maximum and minimum doses below 1.3%.

JOURNAL OF RADIATION RESEARCH (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom

Charles K. Matrosic et al.

Summary: The study aimed to benchmark gel dosimetry measurements in a dynamically deformable abdominal phantom for intrafraction image guidance through a multi-dosimeter comparison. Results showed good agreement between gel dosimeters and ion chamber measurements, as well as the improvement in treatment delivery with the inclusion of the ultrasound image guidance system.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Article Oncology

Empirical quenching correction in radiochromic silicone-based three-dimensional dosimetry of spot-scanning proton therapy

Lia Barbosa Valdetaro et al.

Summary: This study evaluated the viability of an empirical correction model for 3D radiochromic silicone-based dosimeters irradiated with spot-scanning proton therapy. The model successfully corrected for signal quenching effects, allowing for accurate dosimetric measurements in complex dose distributions for proton therapy. Differences in dose response and signal quenching were observed between dosimeters of different sizes.

PHYSICS & IMAGING IN RADIATION ONCOLOGY (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research

Bruce Faddegon et al.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2020)

Article Oncology

Dose-response of deformable radiochromic dosimeters for spot scanning proton therapy

Simon Jensen et al.

PHYSICS & IMAGING IN RADIATION ONCOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Evaluation of an x-ray CT polymer gel dosimetry system in the measurement of deformed dose

E. Maynard et al.

BIOMEDICAL PHYSICS & ENGINEERING EXPRESS (2020)

Review Oncology

Managing treatment-related uncertainties in proton beam radiotherapy for gastrointestinal cancers

Erik J. Tryggestad et al.

JOURNAL OF GASTROINTESTINAL ONCOLOGY (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Clinical implementation of respiratory-gated spot-scanning proton therapy: An efficiency analysis of active motion management

Edgar Gelover et al.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Deformable abdominal phantom for the validation of real-time image guidance and deformable dose accumulation

Charles K. Matrosic et al.

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

ELPHA: Dynamically deformable liver phantom for real-time motion-adaptive radiotherapy treatments

Stefanie Ehrbar et al.

MEDICAL PHYSICS (2019)

Article Engineering, Biomedical

Chemically tuned linear energy transfer dependent quenching in a deformable, radiochromic 3D dosimeter

Ellen Marie Hoye et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Proceedings Paper Radiology, Nuclear Medicine & Medical Imaging

First 3D measurements of proton beams in a deformable silicone-based dosimeter

E. M. Hoye et al.

9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (2017)

Article Engineering, Biomedical

Determining the mechanical properties of a radiochromic silicone-based 3D dosimeter

L. P. Kaplan et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator

Rune Hansen et al.

MEDICAL PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

Dmitri Matenine et al.

MEDICAL PHYSICS (2015)

Article Engineering, Biomedical

Eliminating the dose-rate effect in a radiochromic silicone-based 3D dosimeter

E. M. Hoye et al.

PHYSICS IN MEDICINE AND BIOLOGY (2015)

Article Engineering, Biomedical

FlexyDos3D: a deformable anthropomorphic 3D radiation dosimeter: radiation properties

Y. De Deene et al.

PHYSICS IN MEDICINE AND BIOLOGY (2015)

Proceedings Paper Engineering, Biomedical

A new dosimeter formulation for deformable 3D dose verification

E. M. Hoye et al.

8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) (2015)

Proceedings Paper Physics, Multidisciplinary

How to perform an optical CT scan: an illustrated guide

S. J. Doran

7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE) (2013)

Meeting Abstract Radiology, Nuclear Medicine & Medical Imaging

Quantitative Dose Tracking Enabled Through a Novel Deformable 3D Dosimeter

T. Juang et al.

MEDICAL PHYSICS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

A novel methodology for 3D deformable dosimetry

U. J. Yeo et al.

MEDICAL PHYSICS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

TOPAS: An innovative proton Monte Carlo platform for research and clinical applications

J. Perl et al.

MEDICAL PHYSICS (2012)

Review Engineering, Biomedical

Motion in radiotherapy: particle therapy

C. Bert et al.

PHYSICS IN MEDICINE AND BIOLOGY (2011)

Article Environmental Sciences

Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation

J. Adamovics et al.

RADIATION PROTECTION DOSIMETRY (2006)