4.4 Article

Performance of 3D diamond detectors in small field dosimetry: The impact of pixel size

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

The use of Pantherpix pixel detector in radiotherapy QA

Denis Dudas et al.

Summary: This article introduces a new hybrid pixel detector, Pantherpix, designed specifically for radiotherapy and evaluates its use in radiotherapy photon beams. The study shows that Pantherpix has sufficient clinical quality for relative dosimetry and is applicable for cobalt beam therapy.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2021)

Review Physics, Multidisciplinary

Diamond Detectors for Radiotherapy X-Ray Small Beam Dosimetry

C. Talamonti et al.

Summary: The introduction of new X-Ray treatment machines has driven the development of high conformal radiotherapy techniques, but also presented challenges for clinical dosimetry. In order to address issues in small field dosimetry, it is necessary to compromise between different characteristics, with water equivalence and small highly sensitive volumes being key requirements.

FRONTIERS IN PHYSICS (2021)

Article Instruments & Instrumentation

Intercalibration of a polycrystalline 3D diamond detector for small field dosimetry

K. Kanxheri et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2020)

Article Instruments & Instrumentation

Investigation of 3D diamond detector dosimetric characteristics

K. Kanxheri et al.

JOURNAL OF INSTRUMENTATION (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Characterization and clinical evaluation of a novel 2D detector array for conventional and flattening filter free (FFF) IMRT pre-treatment verification

Yuvaraj Sekar et al.

ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK (2018)

Article Engineering, Biomedical

Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?

Vanessa De Coste et al.

PHYSICS IN MEDICINE AND BIOLOGY (2017)

Article Instruments & Instrumentation

Polycrystalline diamond detectors with three-dimensional electrodes

S. Lagomarsino et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2015)

Article Physics, Applied

Three-dimensional diamond detectors: Charge collection efficiency of graphitic electrodes

S. Lagomarsino et al.

APPLIED PHYSICS LETTERS (2013)

Article Oncology

A methodological approach to reporting corrected small field relative outputs

Gavin Cranmer-Sargison et al.

RADIOTHERAPY AND ONCOLOGY (2013)

Article Instruments & Instrumentation

Present limitations of CVD diamond detectors for IMRT applications

C. De Angelis et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2007)

Article Instruments & Instrumentation

Influence of temperature on the response of high-quality polycrystalline diamond detectors

R. D'Alessandro et al.

NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

An investigation of the operating characteristics of two PTW diamond detectors in photon and electron beams

C De Angelis et al.

MEDICAL PHYSICS (2002)