4.7 Article

Transferrin analysis in wistar rats plasma: Towards an electrochemical point-of-care approach for the screening of alcohol abuse

期刊

MICROCHEMICAL JOURNAL
卷 181, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2022.107738

关键词

Alcoholism screening; Diagnosis; Point-of-care testing; Disposable electrodes; Animal model testing; Rat plasma

资金

  1. TRANSNANOAVANSENS program from the Community of Madrid [P2018/NMT-4349]
  2. Spanish Ministry of Economy, Industry and Competitiveness [CTQ2017-86441-C2-1-R, PID2020- 118154 GB-I00, MCIN/AEI/ 10.13039/501100011033]
  3. Spanish Ministry of Health (Plan Nacional de Drogas 2021) [2021I043]
  4. Universidad de Alcala (FPI fellowship (T.S), Spain)

向作者/读者索取更多资源

A disposable electrochemical sensor was proposed for the diagnosis of chronic alcohol abuse, which assessed the biomarker carbohydrate deficient transferrin using the parameter Electrochemical index of glycosylation (EIG). The sensor exhibited a good limit of detection and showed promising clinical sensitivity and specificity, making it a potential useful tool for point-of-care testing of alcohol abuse.
Simple and low-cost point-of-care testing (POCT) approaches are necessary not only for the diagnosis of alcohol abuse but also for the follow-up of patients during the treatment of alcohol dependence. To advance the development towards these approaches, a disposable screen printed-based electrochemical sensor is proposed for the diagnosis of chronic alcohol abuse. The selected biomarker to be screened (and followed up) was the carbohydrate deficient transferrin (CDT), which was assessed using the parameter Electrochemical index of glycosylation (EIG). EIG is defined as the ratio between the signal generated by carbohydrates present in transferrin (Tf) (selectively labeled with an Os(VI) tag) and the signal generated by the electroactive amino acids present in Tf, measured by adsorptive transfer square wave voltammetry (AdTSWV). The electrochemical sensor exhibited a good limit of detection (LOD <= 0.7 g L-1) well below the normal range of transferrin in serum (ranging from 2 to 3.6 g L-1). In addition, the diagnostic capabilities of the sensor were evaluated in plasma rats from 31 individuals (16 chronically exposed to alcohol and 15 saline control), yielding a very good clinical sensitivity and specificity (81% and 87%, respectively). These results draw the potential of this approach to be used for POCT of alcohol abuse, making it a useful tool to help therapists/clinicians even patient's family in the follow-up of alcohol rehabilitation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据