4.5 Article

Satisfactory results after endoscopic gluteus medius repair combined with selective gluteus maximus reflected tendon release for the treatment of a full-thickness tear of gluteus medius

期刊

KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY
卷 31, 期 5, 页码 2038-2045

出版社

SPRINGER
DOI: 10.1007/s00167-022-07140-x

关键词

Gluteus medius full-thickness tear; Gluteus maximus reflected tendon release; Endoscopy; Hip arthroscopy; Surgical technique

向作者/读者索取更多资源

The study aimed to report the mid-term follow-up results of endoscopic gluteus medius repair combined with a systematic release of the gluteus maximus reflected tendon. The surgical method was found to significantly improve hip function and reduce pain in patients with a full-thickness tear of the gluteus medius tendon, and no major complications were reported.
Purpose The current study aimed to report the mid-term follow-up results of endoscopic gluteus medius repair combined with a systematic release of the gluteus maximus reflected tendon. Methods Twenty-two patients with a symptomatic full-thickness tear of the gluteus medius tendon, as diagnosed by clinical examination and imaging (MRI), and who had a failure of conservative treatment for at least 6 months, were retrospectively enrolled for this study. An endoscopic repair of gluteus medius was performed for all patients in combination with gluteus maximus reflected tendon release according to the Polesello technique. The Visual Analogue Scale (VAS) for pain, Modified Harris Hip Score (mHHS), Lower Extremity Functional Scale (LEFS), Hip Outcome Score-Activity Daily Life (HOS-ADL), and Hip Outcome Score-Sport Specific Subscale (HOS-SSS) were administered to each patient before surgery for 6 months, 1 year, and every following year after surgery. Results All analysed hip scores (mHHS, LEFS, HOS-ADL, and HOS-SSS) showed statistically significant improvements between the pre-operative and post-operative values at 6 months, 1 year, and the latest follow-up appointments after surgery (p < 0.001). The mean pre-operative pain was 8.6 +/- 1.0 on the VAS. After surgical treatment, the pain was significantly reduced (p < 0.001) on the VAS at 6 months (5.4 +/- 1.5), 1 year (4.4 +/- 1.8) and the latest follow-up control visit (3.6 +/- 2.2). No patient-reported major complications (re-rupture, deep infection or neurovascular injury). Eleven (50%) patients indicated the results as excellent, 7 (32%) as good, 2 (9%) as fair, and 2 (9%) as poor. Conclusion The use of abductor tendon repair in combination with a systematic release of the reflected tendon of the gluteus maximus according to the Polesello technique seems to be a safe and effective endoscopic way of treating a full-thickness tear of the gluteus medius.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据