4.5 Article

A new approach for accurately measuring the spectral emissivity via modulating the surrounding radiation

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.jqsrt.2022.108277

关键词

Spectral emissivity; Emissivity measurement apparatus; Surrounding radiation; Accuracy improvement

资金

  1. National Natural Science Foundation of China [U1804261, 62075058]
  2. Innovation Scientists and Technicians Troop Construction Projects of Henan Province [2240 0 0510 0 07]
  3. Natural Science Foundation of Henan Province [22230 0420 011, 22230 0420209]
  4. Key Scientific Research Project of Colleges and Universities in Henan Province [22A140021]
  5. Key Scientific and Technological Project of Xinxiang City [GG2020002]
  6. Outstanding Youth Foundation of Henan Normal University [20200171]

向作者/读者索取更多资源

An improved method for measuring spectral emissivity by modulating the surrounding radiation is proposed in this study. A measurement apparatus is constructed and validated, and the results demonstrate the reliability and accuracy of the proposed method.
Accurately measuring the spectral emissivity is of significant importance in thermal radiation. In this study, an improved measurement method for determination of spectral emissivity via modulating the surrounding radiation is proposed. A proof-of-concept measuring apparatus is constructed, and the main component parts are described in detail. The temperature uniformity of the isothermal aperture is verified, and the impact of the temperature uniformity on the emissivity measurements is studied. The good linearity and long-term stability of the detector is evaluated to ensure the validity of the improved method. The potential reference materials (silicon carbide and Armco iron) were used to validate the reliability and the accuracy of the measurement apparatus. The excellent data consistency of both two reference materials with the literature data demonstrates the reliability of the improved method and the measurement apparatus. The performance of the measurement apparatus with and without the isothermal aperture is compared, and the necessity of the modulated surrounding radiation is validated. The calculated combined uncertainty for the SiC sample at 1073 K is better than 2.38 %. The superior performance of the emissivity measurement apparatus indicate that the improved method proposed in this work provides a new approach for accurately measuring the spectral emissivity.(c) 2022 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据