4.6 Article

Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents

期刊

JOURNAL OF NEURAL ENGINEERING
卷 19, 期 5, 页码 -

出版社

IOP Publishing Ltd
DOI: 10.1088/1741-2552/ac8dc4

关键词

volume conduction; microstimulators; implants; ASIC; wireless power transfer; hermeticity

资金

  1. European Research Council (ERC) under the European Union [724244]
  2. ICREA under the ICREA Academia programme
  3. European Research Council (ERC) [724244] Funding Source: European Research Council (ERC)

向作者/读者索取更多资源

This study developed threadlike wireless implantable neuromuscular microstimulators that are digitally addressable and demonstrated their feasibility in vivo. These microstimulators can be minimally invasively implanted and controlled independently, providing a potential basis for advanced motor neuroprostheses with dense networks of wireless devices.
Objective. To develop and in vivo demonstrate threadlike wireless implantable neuromuscular microstimulators that are digitally addressable. Approach. These devices perform, through its two electrodes, electronic rectification of innocuous high frequency current bursts delivered by volume conduction via epidermal textile electrodes. By avoiding the need of large components to obtain electrical energy, this approach allows the development of thin devices that can be intramuscularly implanted by minimally invasive procedures such as injection. For compliance with electrical safety standards, this approach requires a minimum distance, in the order of millimeters or a very few centimeters, between the implant electrodes. Additionally, the devices must cause minimal mechanical damage to tissues, avoid dislocation and be adequate for long-term implantation. Considering these requirements, the implants were conceived as tubular and flexible devices with two electrodes at opposite ends and, at the middle section, a hermetic metallic capsule housing the electronics. Main results. The developed implants have a submillimetric diameter (0.97 mm diameter, 35 mm length) and consist of a microcircuit, which contains a single custom-developed integrated circuit, housed within a titanium capsule (0.7 mm diameter, 6.5 mm length), and two platinum-iridium coils that form two electrodes (3 mm length) located at opposite ends of a silicone body. These neuromuscular stimulators are addressable, allowing to establish a network of microstimulators that can be controlled independently. Their operation was demonstrated in an acute study by injecting a few of them in the hind limb of anesthetized rabbits and inducing controlled and independent contractions. Significance. These results show the feasibility of manufacturing threadlike wireless addressable neuromuscular stimulators by using fabrication techniques and materials well established for chronic electronic implants. Although long-term operation still must be demonstrated, the obtained results pave the way to the clinical development of advanced motor neuroprostheses formed by dense networks of such wireless devices.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论