Volume-Controlled 19F MR Ventilation Imaging of Fluorinated Gas

期刊

JOURNAL OF MAGNETIC RESONANCE IMAGING
卷 57, 期 4, 页码 1114-1128

出版社

WILEY
DOI: 10.1002/jmri.28385

关键词

F-19; pulmonary MRI; repeatability; inspiratory volume control

向作者/读者索取更多资源

This study evaluated the repeatability of F-19 ventilation MRI and its correlation with lung function testing. The results showed that using inspiratory volume control in MRI improved the correlation and repeatability of imaging parameters with lung function testing.
Background F-19 MRI of inhaled gas tracers has developed into a promising tool for pulmonary diagnostics. Prior to clinical use, the intersession repeatability of acquired ventilation parameters must be quantified and maximized. Purpose To evaluate repeatability of static and dynamic F-19 ventilation parameters and correlation with predicted forced expiratory volume in 1 second (FEV1%pred) with and without inspiratory volume control. Study Type Prospective. Population A total of 30 healthy subjects and 26 patients with chronic obstructive pulmonary disease (COPD). Field Strength/Sequence Three-dimensional (3D) gradient echo pulse sequence with golden-angle stack-of-stars k-space encoding at 1.5 T. Assessment All study participants underwent F-19 ventilation MRI over eight breaths with inspiratory volume control (w VC) and without inspiratory volume control (w/o VC), which was repeated within 1 week. Ventilated volume percentage (VVP), fractional ventilation (FV), and wash-in time (WI) were computed. Lung function testing was conducted on the first visit. Statistical Tests Correlation between imaging and FEV1%pred was measured using Pearson correlation coefficient (r). Differences in imaging parameters between first and second visit were analyzed using paired t-test. Repeatability was quantified using intraclass correlation coefficient (ICC) and coefficient of variation (CoV). Minimum detectable effect size (MDES) was calculated with a power analysis for study size n = 30 and a power of 0.8. All hypotheses were tested with a significance level of 5% two sided. Results Strong and moderate linear correlations with FEV1%pred for COPD patients were found in almost all imaging parameters. The ICC w VC exceeds the ICC w/o VC for all imaging parameters. CoV was significantly lower w VC for initial VVP in COPD patients, FV, CoV FV, WI and standard deviation (SD) of WI. MDES of all imaging parameters were smaller w VC. Data Conclusion F-19 gas wash-in MRI with inspiratory volume control increases the correlation and repeatability of imaging parameters with lung function testing. Evidence Level 2 Technical Efficacy Stage 2

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据