4.7 Article

Estimation of Cerebral Blood Flow and Arterial Transit Time From Multi-Delay Arterial Spin Labeling MRI Using a Simulation-Based Supervised Deep Neural Network

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Deep Learning Staging of Liver Iron Content From Multiecho MR Images

Vincenzo Positano et al.

Summary: This study developed a deep-learning method for unsupervised classification of liver iron content (LIC) from TEE multiecho MR images. The results showed that the HippoNet-Ensemble network achieved higher accuracy, sensitivity, and specificity in LIC staging compared to other networks.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

The Utility of Arterial Transit Time Measurement for Evaluating the Hemodynamic Perfusion State of Patients with Chronic Cerebrovascular Stenosis or Occlusive Disease: Correlative Study between MR Imaging and 15O-labeled H2O Positron Emission Tomography

Kayo Takeuchi et al.

Summary: This study aimed to investigate the accuracy of arterial transit time (ATT) mapping and its correlation with positron emission tomography (PET)-oxygen extraction fraction (OEF) and PET-mean transit time (MTT) in patients with unilateral major cerebral artery stenosis or occlusion. ASL-MRI with different post-label delay (PLD) settings was performed, and ATT maps were obtained using a low-resolution pre-scan approach. Results showed that ATT correction improved the correlation between ASL-CBF and PET-CBF, with the best correlation found for a PLD of 2.0s with ATT correction. ATT was also found to be correlated with PET-OEF and MTT ratio.

MAGNETIC RESONANCE IN MEDICAL SCIENCES (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

An Unsupervised Deep Learning Approach for Dynamic-Exponential Intravoxel Incoherent Motion MRI Modeling and Parameter Estimation in the Liver

Xin-Xiang Zhou et al.

Summary: This study proposes an unsupervised deep learning approach for voxel-wise dynamic-exponential IVIM modeling and parameter estimation in liver imaging. The proposed method shows high accuracy and robustness in both simulation and in vivo measurements.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Separating spin compartments in arterial spin labeling using delays alternating with nutation for tailored excitation (DANTE) pulse: A validation study using T2-relaxometry and application to arterial cerebral blood volume imaging

Shota Ishida et al.

Summary: The study demonstrates that DANTE is able to eliminate microvascular compartment signals from ASL imaging, and shows the feasibility of measuring CBVa using Hadamard-encoded DANTE-ASL in combination with a simplified two-compartment model. Significant increases in CBF and CBVa were observed in rest and breath-holding tasks.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Automated generation of cerebral blood flow and arterial transit time maps from multiple delay arterial spin-labeled MRI

Nicholas J. Luciw et al.

Summary: This study developed and evaluated a deep learning approach to estimate CBF and ATT from multiple PLD ASL MRI. Different convolutional neural network architectures were trained and compared, and the U-Net model showed better performance. The U-Net model had lower MAE on both training and test data, and demonstrated good generalizability.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Computer Science, Interdisciplinary Applications

Deep-ASL enhancement technique in arterial spin labeling MRI - A novel approach for the error reduction of partial volume correction technique with linear regression algorithm

A. Shyna et al.

Summary: This study proposes a deep learning based ASL enhancement algorithm, which employs single image super resolution and multi-loss joint strategy to improve the resolution and accuracy of ASL images. By training the algorithm using simulated ASL images and validating it with clinical ASL images, the results demonstrate that the algorithm can provide more accurate estimation of cerebral blood flow.

JOURNAL OF COMPUTATIONAL SCIENCE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Arterial Transit Time-Based Multidelay Combination Strategy Improves Arterial Spin Labeling Cerebral Blood Flow Measurement Accuracy in Severe Steno-Occlusive Diseases

Shiori Amemiya et al.

Summary: The study found that in severe steno-occlusive diseases, the Combo strategy using ATT correction can improve CBF measurement accuracy, and VS significantly enhances CBF measurement accuracy in standard protocol and in moyamoya patients for the Combo.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Improved unsupervised physics-informed deep learning for intravoxel incoherent motion modeling and evaluation in pancreatic cancer patients

Misha P. T. Kaandorp et al.

Summary: This study presents an improved version IVIM-NEToptim, which outperforms previous IVIM-NETorig and other state-of-the-art intravoxel-incoherent motion (IVIM) fitting approaches to diffusion-weighted imaging (DWI). IVIM-NEToptim shows superior accuracy, independence, and consistency in simulations and in vivo, making it a recommended choice for IVIM fitting to DWI data.

MAGNETIC RESONANCE IN MEDICINE (2021)

Proceedings Paper Engineering, Biomedical

Deep learning and multi-contrast based denoising for low-SNR Arterial Spin Labeling (ASL) MRI

Enhao Gong et al.

Summary: The study introduces a deep learning algorithm that improves the image quality and stability of ASL technique by combining convolutional neural network and multiple tissue contrast information, outperforming traditional denoising algorithms and standard deep learning denoising methods.

MEDICAL IMAGING 2020: IMAGE PROCESSING (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Deep learning how to fit an intravoxel incoherent motion model to diffusion-weighted MRI

Sebastiano Barbieri et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Intravascular signal suppression and microvascular signal mapping using delays alternating with nutation for tailored excitation (DANTE) pulse for arterial spin labeling perfusion imaging

Yasuhiro Fujiwara et al.

MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Denoising arterial spin labeling perfusion MRI with deep machine learning

Danfeng Xie et al.

MAGNETIC RESONANCE IMAGING (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

A general framework for optimizing arterial spin labeling MRI experiments

Joseph G. Woods et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Review Endocrinology & Metabolism

Consensus statement on current and emerging methods for the diagnosis and evaluation of cerebrovascular disease

Manus J. Donahue et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Three-dimensional arterial spin labeling imaging with a DANTE preparation pulse

Tsuyoshi Matsuda et al.

MAGNETIC RESONANCE IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Multi-delay arterial spin labeling perfusion MRI in moyamoya disease-comparison with CT perfusion imaging

Rui Wang et al.

EUROPEAN RADIOLOGY (2014)

Article Geosciences, Multidisciplinary

Root mean square error (RMSE) or mean absolute error (MAE)? - Arguments against avoiding RMSE in the literature

T. Chai et al.

GEOSCIENTIFIC MODEL DEVELOPMENT (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Volumetric measurement of perfusion and arterial transit delay using hadamard encoded continuous arterial spin labeling

Weiying Dai et al.

MAGNETIC RESONANCE IN MEDICINE (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Reduced resolution transit delay prescan for quantitative continuous arterial spin labeling perfusion imaging

Weiying Dai et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Separation of Macrovascular Signal in Multi-inversion Time Arterial Spin Labelling MRI

Michael A. Chappell et al.

MAGNETIC RESONANCE IN MEDICINE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

Continuous Flow-Driven Inversion for Arterial Spin Labeling Using Pulsed Radio Frequency and Gradient Fields

Weiying Dai et al.

MAGNETIC RESONANCE IN MEDICINE (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla

JJ Wang et al.

MAGNETIC RESONANCE IN MEDICINE (2002)