期刊
JOURNAL OF INSTRUMENTATION
卷 11, 期 -, 页码 -出版社
IOP PUBLISHING LTD
DOI: 10.1088/1748-0221/11/07/P07010
关键词
Pattern recognition; cluster finding; calibration and fitting methods; Interaction of radiation with matter; Gaseous detectors; Wire chambers (MWPC, Thin-gap chambers, drift chambers, drift tubes, proportional chambers etc)
资金
- European Commission through the Research Fund for Coal and Steel [RFSR-CT-2014-00027]
We demonstrate that muon tomography can be used to precisely measure the properties of various materials. The materials which have been considered have been extracted from an experimental blast furnace, including carbon (coke) and iron oxides, for which measurements of the linear scattering density relative to the mass density have been performed with an absolute precision of 10%. We report the procedures that are used in order to obtain such precision, and a discussion is presented to address the expected performance of the technique when applied to heavier materials. The results we obtain do not depend on the specific type of material considered and therefore they can be extended to any application.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据