4.5 Article

Simultaneous quantification of urinary tobacco and marijuana metabolites using solid-supported liquid-liquid extraction coupled with liquid chromatography tandem mass spectrometry

出版社

ELSEVIER
DOI: 10.1016/j.jchromb.2022.123378

关键词

Trans-3'-hydroxycotinine; Cotinine; 11-nor-9-carboxy-delta 9-tetrahydrocannabinol; Supported liquid extraction; Tobacco metabolites; Marijuana metabolites

资金

  1. National Institutes of Health [NIH-R01NR014800, NIH-R01MD009064, NIH-R24ES029490, NIH-R01MD009746 NIH-P50ES02607, NIH-P30ES019776, NIH-UH3OD023318, NIH-U2CES026560, NIH-U2CES026542]
  2. US Environmental Protection Agency [EPA-83615301]

向作者/读者索取更多资源

To assess the combined health risks of co-exposure to tobacco and marijuana, researchers have developed an analytical method to simultaneously measure tobacco and marijuana metabolites. This method reduces laboratory costs and sample volume, making it suitable for large-scale sample analysis.
Co-exposure to tobacco and marijuana has become common in areas where recreational marijuana use is legal. To assist in the determination of the combined health risks of this co-exposure, an analytical method capable of simultaneously measuring tobacco and marijuana metabolites is needed to reduce laboratory costs and the required sample volume. So far, no such analytical method exists. Thus, we developed and validated a method to simultaneously quantify urinary levels of trans-3'-hydroxycotinine (3OH-COT), cotinine (COT), and 11-nor-9-carboxy-delta 9-tetrahydrocannabinol (COOH-THC) to assess co-exposure to tobacco and marijuana. Urine (200 mu L) was spiked with labelled internal standards and enzymatically hydrolyzed to liberate the conjugated analytes before extraction using solid-supported liquid-liquid extraction (SLE) with ethyl acetate serving as an eluent. The target analytes were separated on a C18 (4.6 x 100 mm, 5 mu m) analytical column with a gradient mobile phase elution and analyzed using tandem mass spectrometry with multiple reaction monitoring of target ion transitions. Positive electrospray ionization (ESI) was used for 3OH-COT and COT, while negative ESI was used for COOH-THC. The total run time was 13 min. The extraction recoveries were 18.4-23.9 % (3OH-COT), 65.1-96.8 % (COT), and 80.6-95.4 % (COOH-THC). The method limits of quantification were 5.0 ng/mL (3OH-COT) and 2.5 ng/mL (COT and COOH-THC). The method showed good accuracy (82.5-98.5 %) and precision (1.22-6.21 % within-day precision and 1.42-6.26 % between-day precision). The target analytes were stable for at least 144 h inside the autosampler (10 ?). The analyses of reference materials and 146 urine samples demonstrated good method performance. The use of a 96-well plate for preparation makes the method useful for the analysis of large numbers of samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据