Graphene and graphene-derived substances are cutting-edge materials in the field of analytical chemistry. This study evaluated the performance of SiGO-C18ec particles with different diameters in capillary LC columns and compared them with traditional C18 columns. The results showed that the 5 μm SiGO-C18ec particles exhibited the best peak capacity in 15 minutes and outperformed the C18 columns. Additionally, significant orthogonality was found between the SiGO-C18ec and C18 phases.
Graphene and graphene-derived substances are cutting-edge materials receiving increasing attention in the analytical chemistry field. Graphene oxide sheets bonded to amino silica particles functionalized with octadecyl (C18) groups and endcapped, also known as SiGO-C18ec, have been successfully employed as extraction phases and in analytical columns associated with conventional liquid chromatography (LC). In this work, SiGO-C18ec particles of 3, 5, and 10 pm nominal id were employed to pack capillary LC columns (100 mm long x 0.3 mm id), and their performance in the gradient mode was evaluated and compared. A 3 pm C18 capillary LC column (50 x 0.3 mm) was used as a reference column. Eight analytes having different polarities and topological surface areas were selected as a probe in this study: carbofuran clomazone, hexazinone, carbamazepine, citalopram, clomipramine, desipramine, and ochratoxin A. Studies about orthogonality were performed to investigate the orthogonality between the SiGO-C18ec and C18 phases. Among the SiGO-C18ec phases investigated, the column packed with 5 pm SiGO-C18ec particles presented the best peak capacity (29) in 15 min. Additionally, the performance of the columns packed with 5 pm SiGO-C18ec particles overcame the performance of the C18 columns used. Significant orthogonality was found between C18 and SiGO-C18ec packed columns; however, no significant differences were found between columns packed with SiGO-C18ec particles of different diameters. (c) 2022 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据