4.2 Article

LC-MS-MS Determination of Cytostatic Drugs on Surfaces and in Urine to Assess Occupational Exposure

期刊

JOURNAL OF ANALYTICAL TOXICOLOGY
卷 46, 期 9, 页码 E248-E255

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/jat/bkac073

关键词

-

向作者/读者索取更多资源

The increased usage of cytostatic drugs poses a high risk of exposure among healthcare workers. This study describes the development and full validation of two liquid chromatography-tandem mass spectrometry methods for the detection of multiple drugs in working surfaces and urine samples. These validated methods allow for a comprehensive evaluation of both environmental and biological contamination in hospital settings and healthcare workers.
The ever-increased usage of cytostatic drugs leads to high risk of exposure among healthcare workers. Moreover, workers are exposed to multiple compounds throughout their lives, leading to cumulative and chronic exposure. Therefore, multianalyte methods are the most suitable for exposure assessment, which minimizes the risks from handling cytostatic drugs and ensures adequate contamination containment. This study describes the development and full validation of two liquid chromatography-tandem mass spectrometry methods for the detection of gemcitabine, dacarbazine, methotrexate, irinotecan, cyclophosphamide, doxorubicinol, doxorubicin, epirubicin, etoposide, vinorelbine, docetaxel and paclitaxel in working surfaces and urine samples. The urine method is the first to measure vinorelbine and doxorubicinol. For surfaces, limits of detection (LOD) and limits of quantification (LOQ) were 5-100 pg/cm(2), and linearity was achieved up to 500 pg/cm(2). Inaccuracy was between -11.0 and 8.4%. Intra-day, inter-day and total imprecision were <20%, except for etoposide and irinotecan (<22.1%). In urine, LOD and LOQ were 5-250 pg/mL, with a linear range up to 1,000-5,000 pg/mL. Inaccuracy was between -3.8 and 14.9%. Imprecision was <12.4%. Matrix effect was from -58.3 to 1,268.9% and from -66.7 to 1,636% in surface and urine samples, respectively, and extraction efficiency from 10.8 to 75% and 47.1 to 130.4%, respectively. All the analytes showed autosampler (6 degrees C/72 h), freezer (-22 degrees C/2 months) and freeze/thaw (three cycles) stability. The feasibility of the methods was demonstrated by analyzing real working surfaces and patients' urine samples. Contamination with gemcitabine, irinotecan, cyclophosphamide, epirubicin and paclitaxel (5-4,641.9 pg/cm(2)) was found on biological safety cabinets and outpatients' bathrooms. Analysis of urine from patients under chemotherapy identified the infused drugs at concentrations higher than the upper LOQ. These validated methods will allow a comprehensive evaluation of both environmental and biological contamination in hospital settings and healthcare workers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据