4.4 Article

A Sensitive Amperometric Sensor based on CuO and molecularly imprinted polymer composite for Determination of Danazol in human urine

出版社

ELSEVIER
DOI: 10.20964/2022.11.72

关键词

CuO nanostructure; Molecularly Imprinted Polymers; Specificity; Danazol; bodybuilders; Amperometry

向作者/读者索取更多资源

The goal of this study was to create a new sensor for the selective detection of Danazol (DZ) as a doping agent in athlete biological fluid samples using a CuO nanostructured electrode and molecular imprinting. The results showed improved electrocatalytic activity and selectivity of the sensor due to the synergistic effect of CuO and MIPs. The sensor demonstrated a linear response from 0 to 6900 ng/mL, a sensitivity of 0.02576 mu A/ng.mL-1, and a limit of detection of 0.10 ng/mL. The sensor also showed notable electrocatalytic performance and appropriate precision for practical analyses in urine and other biological fluids samples.
The goal of this study was to create a new molecular imprinting-based sensor on a CuO nanostructured electrode for the selective detection of Danazol (DZ) as a doping agent in athlete biological fluid samples. CuO nanostructured film was electrodeposited on the screen-printed carbon electrode (CuO/SPCE) for the fabrication of modified electrodes, and molecularly imprinted polymer (MIP) was electropolymerized on CuO/SPCE. The analysis of FE-SEM images and XRD patterns on modified electrodes revealed that electropolymerization of amorphous MIP on CuO nanoparticles was successful. Electrochemical analyses using CV and amperometry revealed that the synergistic effect of CuO and MIPs significantly improved the electrocatalytic activity and selectivity of the MIP/CuO nanostructure. The results showed that a linear response from 0 to 6900 ng/mL was obtained. MIP/CuO/SPCE sensitivity was determined to be 0.02576 mu A/ng.mL-1, and the limit of detection was determined to be 0.10 ng/mL. When the proposed method was compared to some previously reported DZ sensors, MIP/CuO/SPCE demonstrated notable electrocatalytic performance with the lowest limit of detection value. The MIP/CuO/SPCE sensing system was studied for the analysis of DZ in real samples prepared from the urine of five bodybuilders, and the results showed that the RSD values (3.55% to 4.41%) are appropriate for valid and accurate practical analyses in urine and other biological fluids samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据