Development and validation of cell-based luciferase reporter gene assays for measuring neutralizing anti-drug antibodies against interferon beta

期刊

JOURNAL OF IMMUNOLOGICAL METHODS
卷 430, 期 -, 页码 1-9

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2016.01.004

关键词

Anti-drug antibodies; Neutralizing antibodies; Bioassay; Luciferase; Interferon beta; Multiple sclerosis

向作者/读者索取更多资源

Neutralizing anti-drug antibodies (NAbs) against therapeutic interferon beta (IFN beta) in people with multiple sclerosis (MS) are measured with cell-based bioassays. The aim of this study was to redevelop and validate two luciferase reporter-gene bioassays, LUC and iLite, using a cut-point approach to identify NAb positive samples. Such an approach is favored by the pharmaceutical industry and governmental regulatory agencies as it has a clear statistical basis and overcomes the limitations of the current assays based on the Kawade principle. The work was conducted following the latest assay guidelines. The assays were re-developed and validated as part of the Anti-Biopharmaceutical Immunization: Prediction and analysis of clinical relevance to minimize the risk (ABIRISK) consortium and involved a joint collaboration between four academic laboratories and two pharmaceutical companies. The LUC assay was validated at Innsbruck Medical University (LUCIMU) and at Rigshospitalet (LUCRH) Copenhagen, and the iLite assay at Karolinska Institutet, Stockholm. For both assays, the optimal serum sample concentration in relation to sensitivity and recovery was 2.5% (v/v) in assay media. A Sha-piro-Wilk test indicated a normal distribution for the majority of runs, allowing a parametric approach for cut point calculation to be used, where NAb positive samples could be identified with 95% confidence. An analysis of means and variances indicated that a floating cut-point should be used for all assays. The assays demonstrated acceptable sensitivity for being cell-based assays, with a confirmed limit of detection in neat serum of 1519 ng/mL for LUCIMU, 814 ng/mL for LUCRH, and 320 ng/mL for iLite. Use of the validated cut-point assay, in comparison with the previously used Kawade method, identified 14% more NAb positive samples. In conclusion, implementation of the cut-point design resulted in increased sensitivity to detect NAbs. However, the clinical significance of these low positive titers needs to be further evaluated. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据