4.2 Article

Testing for myositis specific autoantibodies: Comparison between line blot and immunoprecipitation assays in 57 myositis sera

期刊

JOURNAL OF IMMUNOLOGICAL METHODS
卷 433, 期 -, 页码 1-5

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.jim.2016.02.017

关键词

Myositis; Autoantibodies; Immunoprecipitation; Line blot; Anti-synthetase syndrome; Anti-Jo1

向作者/读者索取更多资源

Objective: To analyze the performance of a line blot assay for the identification of autoantibodies in sera of patients affected by myositis, compared with immunoprecipitation (IP) as gold standard. Methods: 66 sera of patients with myositis (23 polymyositis, 8 anti-synthetase syndromes, 29 dermatomyositis and 6 overlap syndromes) were tested by commercial LB (Euroimmun, Lubeck, Germany); 57 sera were analyzed also by IP of K562 cell extract radiolabeled with S-35-methionine. Inter-rater agreement was calculated with Cohen's k coefficient. Results: Myositis-specific antibodies (MSA) were detected in 36/57 sera (63%) by IP and in 39/66 sera (59%) by LB. The most frequent MSA found by LB were anti-Jo1 and anti-Mi2 found in 15% (10/66) of sera, followed by anti-NXP2 and anti-SRP detected in 106% (7/66) of sera. Anti-TIF1 gamma and anti-MDA5 were found in 6 (9%) and 5 sera (7.6%), respectively. A good agreement between methods was found only for anti-TIF1 gamma, anti-MDA5 and anti-NXP-2 antibodies, while a moderate agreement was estimated for anti-Mi2 and anti-EJ. By contrast, a high discordance rate for the detection of anti-Jo1 antibodies was evident (k: 03). Multiple positivity for MSA were found in 11/66 (17%) by LB and 0/57 by IP (p: 0001). Comparing the clinical features of these 11 sera, we found total discrepancies between assays in 3 sera (27.3%), a relative discrepancy due to the occurrence of one discordant autoantibody (not confirmed by IP) in 5 cases (455%) and a total discrepancy between LB and IP results, but with a relative concordance with clinical features were found in other 3 sera (273%). The semiquantitative results do not support the interpretation of the data. Conclusions: The use of LB assay allowed the detection of new MSA, such as anti-MDA5, anti-MJ and anti-TIF1 gamma antibodies, previously not found with routine methods. However, the high prevalence of multiple positivities and the high discondant rate of anti-Jo1 antibodies could create some misinterpretation of the results from the clinical point of view. These data should be confirmed by enlarging the number of myositis cases. (C) 2016 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据