4.7 Article

Super-Resolved Microbubble Localization in Single-Channel Ultrasound RF Signals Using Deep Learning

期刊

IEEE TRANSACTIONS ON MEDICAL IMAGING
卷 41, 期 9, 页码 2532-2542

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TMI.2022.3166443

关键词

Ultrasonic imaging; Transducers; RF signals; Superresolution; Location awareness; Acoustics; Radio frequency; Convolutional neural network; deep-learning; high-density contrast sources; low-frequency ultrasound; monodisperse microbubbles; super-resolution ultrasound

资金

  1. High Tech for a Sustainable Future

向作者/读者索取更多资源

In this study, an alternative super-resolution approach for ultrasound imaging is proposed, which utilizes a neural network to directly deconvolve single-channel ultrasound radio-frequency signals. The results demonstrate that this method can improve the axial resolution of ultrasound imaging and is sensitive to microbubble density.
Recently, super-resolution ultrasound imaging with ultrasound localization microscopy (ULM) has received much attention. However, ULM relies on low concentrations of microbubbles in the blood vessels, ultimately resulting in long acquisition times. Here, we present an alternative super-resolution approach, based on direct deconvolution of single-channel ultrasound radio-frequency (RF) signals with a one-dimensional dilated convolutional neural network (CNN). This work focuses on low-frequency ultrasound (1.7 MHz) for deep imaging (10 cm) of a dense cloud of monodisperse microbubbles (up to 1000 microbubbles in the measurement volume, corresponding to an average echo overlap of 94%). Data are generated with a simulator that uses a large range of acoustic pressures (5-250 kPa) and captures the full, nonlinear response of resonant, lipid-coated microbubbles. The network is trained with a novel dual-loss function, which features elements of both a classification loss and a regression loss and improves the detection-localization characteristics of the output. Whereas imposing a localization tolerance of 0 yields poor detection metrics, imposing a localization tolerance corresponding to 4% of the wavelength yields a precision and recall of both 0.90. Furthermore, the detection improves with increasing acoustic pressure and deteriorates with increasing microbubble density. The potential of the presented approach to super-resolution ultrasound imaging is demonstrated with a delay-and-sum reconstruction with deconvolved element data. The resulting image shows an order-of-magnitude gain in axial resolution compared to a delay-and-sum reconstruction with unprocessed element data.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据