4.8 Article

Influence of Voltage Harmonics on Partial Discharge Diagnostics in Electric Motors Fed by Variable-Frequency Drives

期刊

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS
卷 69, 期 10, 页码 10605-10614

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TIE.2021.3134085

关键词

Partial discharges; Harmonic analysis; Voltage measurement; Insulation; Electric motors; Pollution measurement; Distortion; Electric machines; harmonics; partial discharges (PD) diagnostics; power quality (PQ); sensitivity analysis; variable-frequency drives (VFDs)

向作者/读者索取更多资源

This article investigates the influence of voltage harmonics distortion produced during the variable-speed operation of VFD on PD characteristics. It proposes a framework for properly evaluating harmonics impact in PD for electric motors and correctly estimating stator insulation degradation.
Typically, in partial discharges (PD) diagnostics tests carried out in a laboratory, harmonic content in a voltage waveform is ignored. However, during the operation of variable-frequency drives (VFD)-fed electric motors, the distorted voltage waveform is produced due to the addition of harmonics components in the sinusoidal voltage waveform. The distortion level increases when the VFD is operated at a lower speed ratio. The additional spectral components in the applied voltage waveform can have a significant impact on the PD behavior in the insulation of the electric motor. Therefore, during online PD monitoring, overlooking the harmonic regime in the applied voltage may lead to a false interpretation of PD data. This article investigates the influence of voltage harmonics distortion produced during the variable-speed operation of VFD on PD characteristics. For this purpose, online PD measurements have been carried out by performing a series of experiments on eight VFD-fed motors under variable operating conditions. The PD severity at different harmonic compositions is experimentally investigated by determining various PD characteristic parameters including PD inception voltage, accumulated apparent charge, average discharge current, discharge power, and quadratic rate. Also, two terms Gaussian models have been mathematically developed using 288 data samples to quantify the variations in PD characteristic parameters against distortion parameters. The article proposes a framework for properly evaluating harmonics impact in PD for electric motors and correctly estimating stator insulation degradation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据