4.7 Article

Effects of hindlimb unloading and subsequent reloading on the structure and mechanical properties of Achilles tendon-to-bone attachment

期刊

FASEB JOURNAL
卷 36, 期 10, 页码 -

出版社

WILEY
DOI: 10.1096/fj.202200713R

关键词

Achilles tendon enthesis; collagen II; fibrocartilage; hindlimb suspension; mechanical properties; reloading

资金

  1. Centre National d'Etudes Spatiales (CNES) [4800000797]

向作者/读者索取更多资源

This study examined the effects of mechanical loading on the structure and mechanical properties of the Achilles tendon enthesis. Results showed that soleus atrophy was severe after hindlimb suspension, but calcified fibrocartilage was minimally affected. Non-calcified fibrocartilage surface area decreased, collagen fiber organization was disrupted, and collagen II distribution was altered. Reloading restored the fibrocartilage surface area and collagen II expression. Functionally, unloading resulted in decreased enthesis stiffness and a shift in the site of failure, while reloading restored the original elastic properties and site of failure. These findings have implications for countermeasure exercises during spaceflight.
While muscle and bone adaptations to deconditioning have been widely described, few studies have focused on the tendon enthesis. Our study examined the effects of mechanical loading on the structure and mechanical properties of the Achilles tendon enthesis. We assessed the fibrocartilage surface area, the organization of collagen, the expression of collagen II, the presence of osteoclasts, and the tensile properties of the mouse enthesis both after 14 days of hindlimb suspension (HU) and after a subsequent 6 days of reloading. Although soleus atrophy was severe after HU, calcified fibrocartilage (CFc) was a little affected. In contrast, we observed a decrease in non-calcified fibrocartilage (UFc) surface area, collagen fiber disorganization, modification of morphological characteristics of the fibrocartilage cells, and altered collagen II distribution. Compared to the control group, restoring normal loads increased both UFc surface area and expression of collagen II, and led to a crimp pattern in collagen. Reloading induced an increase in CFc surface area, probably due to the mineralization front advancing toward the tendon. Functionally, unloading resulted in decreased enthesis stiffness and a shift in site of failure from the osteochondral interface to the bone, whereas 6 days of reloading restored the original elastic properties and site of failure. In the context of spaceflight, our results suggest that care must be taken when performing countermeasure exercises both during missions and during the return to Earth.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据