4.5 Article

Clinical feasibility of accelerated diffusion weighted imaging of the abdomen with deep learning reconstruction: Comparison with conventional diffusion weighted imaging

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 154, 期 -, 页码 -

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2022.110428

关键词

Deep learning reconstruction; Diffusion weighted imaging; liver; apparent diffusion coefficient

资金

  1. Soonchunhyang University Research Fund

向作者/读者索取更多资源

This study assessed the clinical feasibility of accelerated deep learning-reconstructed DWI and compared its image quality and acquisition time with conventional DWI. The results showed that DL DWI achieved higher image quality scores and significantly shorter acquisition time compared to conventional DWI.
Purpose: To assess the clinical feasibility of accelerated deep learning-reconstructed diffusion weighted imaging (DWI) and to compare its image quality and acquisition time with those of conventional DWI. Methods: Seventy-four consecutive patients who underwent 3 T abdominal magnetic resonance imaging (MRI) were retrospectively enrolled. DWI were acquired using both conventional DWI and DWI with deep-learning reconstruction (DL DWI). Image quality (overall image quality, anatomic sharpness and details, artifacts, noise, and lesion conspicuity) was scored by two radiologists and compared between two DWI sequences. The apparent diffusion coefficient (ADC) was measured in six locations of the liver parenchyma and focal lesions and compared between two DWI sequences. Results: The mean acquisition time for the DL DWI (216.87 +/- 49.23 sec) was significantly shorter (P < 0.001) than for conventional DWI (358.69 +/- 105.93 sec). DL DWI achieved higher scores than conventional DWI for all qualitative image quality parameters (P < 0.001). DL DWI had a more homogeneous distribution of ADC values throughout the liver, except for the left superior section, compared with conventional DWI. The standard de-viations of the ADC values for all hepatic areas were significantly lower in DL DWI than in conventional DWI (all, P < 0.001). The ADC values for the liver parenchyma and focal hepatic lesions were lower in DL DWI than in conventional DWI. Conclusions: DL DWI is a feasible acquisition technique in clinical routines and provides improved image quality and simultaneously significant reduction in scan time compared with conventional DWI.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据