4.7 Article

Granular activated carbon (GAC) fixed bed adsorption combined with ultrafiltration for shale gas wastewater internal reuse

期刊

ENVIRONMENTAL RESEARCH
卷 212, 期 -, 页码 -

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.envres.2022.113486

关键词

Shale gas flowback and produced water; Granular activated carbon; Ultrafiltration; Internal reuse; Membrane fouling

资金

  1. National Natural Science Foundation of China [52070134]
  2. Sichuan University From 0 to 1innovation research project (transformative technology project)
  3. Sichuan University
  4. Yibin City People's Government strategic cooperation project [2020CDYB-2]

向作者/读者索取更多资源

This study proposed the use of fixed bed adsorption using granular activated carbon (GAC) combined with ultrafiltration (UF) for the treatment of shale gas flowback and produced water (SGFPW). The results showed that GAC fixed bed effectively removed dissolved organic carbon (DOC) and turbidity, mitigating membrane fouling. The integrated GAC fixed bed-UF process produced high-quality effluents that met water quality standards, making it an effective technology for SGFPW reuse.
Membrane processes are widely applied in shale gas flowback and produced water (SGFPW) reuse. However, particulate matters and organic matters aggravate membrane fouling, which is one of the major restrictions on SGFPW reuse. The present study proposed fixed bed adsorption using granular activated carbon (GAC) combined with ultrafiltration (UF) for the first time to investigate the treatment performance and membrane fouling mechanism. The adsorption of GAC for SGFPW was best described by the Temkin isotherm model and the pseudo-second-order kinetic model. GAC fixed bed pretreatment with different empty bed contact times (EBCT) (30, 60 and 90 min) showed the significant removal rate for dissolved organic carbon (DOC) and turbidity, which was 34.7%-42.4% and 98.1%-98.9%, respectively. According to characterization of UF membrane fouling layer, particulate matters and organic matters caused major part of membrane fouling. After being treated by GAC fixed bed, total fouling index (TFI) and hydraulic irreversible fouling index (HIFI) respectively decreased by more than 32.5% and 18.3% respectively, showing the mitigation effect of GAC fixed bed on membrane fouling. According to the XDLVO theory, GAC fixed bed also mitigated membrane fouling by reducing the hydrophobic interactions between the foulants and the UF membrane. The integrated GAC fixed bed-UF process produced high-quality effluents that met the water quality standards of SGFPW internal reuse, which was an effective technology of the SGFPW reuse.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据