Failure analysis of mechanical seal of nitrobenzene sulfuric acid pump

期刊

ENGINEERING FAILURE ANALYSIS
卷 141, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.engfailanal.2022.106660

关键词

Failure analysis; Mechanical seal; Galvanic corrosion; Acid corrosion; Sulfuric acid

向作者/读者索取更多资源

Sulfuric acid pumps have failed multiple times in a chemical plant's nitrobenzene process due to mechanical seal failure. Through examination of the damage characteristics and corrosion effects, it was found that galvanic corrosion, particularly in the sealing gland in contact with the static ring seat, was the main cause of failure. Additionally, suggestions were provided to mitigate the corrosion.
Sulfuric acid pumps serving in the nitrobenzene process failed many times due to the mechanical seal's failure in a chemical plant. To clarify the failure reasons, damage characteristics were examined by visual inspection, scanning electron microscopy, and energy dispersive spectros-copy. Moreover, the possibility of the galvanic corrosion was confirmed by the designed tests, and the effects of the pure sulfuric and mixed acid on the corrosion were also clarified by the im-mersion tests. The results show that the material degrades in the form of intergranular corrosion. The most severe damage locates in the sealing gland, in contact with the static ring seat. Galvanic corrosion is mainly responsible for the failure. The differences in the chemical compositions and the microstructure play an important role in galvanic corrosion. Moreover, some suggestions are provided to alleviate the corrosion based on the analysis above.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据