4.7 Article

Comparative study on loosening of anti-loosening bolt and standard bolt system

期刊

ENGINEERING FAILURE ANALYSIS
卷 140, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.engfailanal.2022.106590

关键词

Bolt -loosening; Pre -loaded bolt; Anti -loosening; Fasteners; Vibration; Self-loosening

资金

  1. Norwegian Research Council [283821]

向作者/读者索取更多资源

This paper investigates the application of anti-loosening bolt system in Offshore Floating Wind Power Systems. By testing different bolt dimensions, the results show that the novel bolt system has superior capacity to withstand self-loosening compared to standard bolts.
In general, bolted connections are exposed to vibrations or repeated over-loads that could lead to self-loosening due to loss of preload. Pre-tensioned bolts in ring flanges are critical parts in Offshore Floating Wind Power Systems, and normally a certain percentage of the installed bolt connections are checked and re-tightened every year. This re-tightening is often done at a high cost and a short weather window due to strong winds and high waves. In this paper, three bolt dimensions (M20, M30 and M42) of the anti-loosening bolt system have been tested. The M30 and M42 bolt systems were preloaded and exposed to transverse oscillating loading, and the loss of preload as a function of load amplitude and number of cycles were measured and compared to standard bolts of HV type, exposed identically. The tested novel bolt system has shown superior capacities to withstand self-loosening, compared to standard bolts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据