4.7 Article

A novel negative carbon-emission, cooling, and power generation system based on combined LNG regasification and waste heat recovery: Energy, exergy, economic, environmental (4E) evaluations

期刊

ENERGY
卷 257, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2022.124528

关键词

LNG cold recovery; Organic Rankine cycle; Negative carbon index; Data center cooling; Medium temperature shift gas; Waste heat recovery

资金

  1. Natural Science Foundation of Shanghai Municipality [22ZR1426900]
  2. Shanghai Municipal Science and Technology Commission [18040501800, 20DZ2252300]
  3. Shanghai Frontiers Science Center of Full Penetration Farreaching Offshore Ocean Energy and Power

向作者/读者索取更多资源

In this paper, a novel negative carbon-emission, cooling, and power generation system is proposed by utilizing LNG cold energy and waste heat recovery. The integrated system shows the best performance when all subsystems are running simultaneously, generating significant power, cooling capacity, and CO2 capture.
In this paper, a novel negative carbon-emission, cooling, and power generation (NCCP) system was proposed to improve the energy efficiency of the liquid natural gas (LNG)-powered hydrogen production plant. With LNG cold energy and waste heat recovery, the NCCP system integrated organic Rankine cycle (ORC) power generation, data center cooling, and CO2 capture. The NCCP system could operate under seven scenarios and the system performance evaluations were performed via energy, exergy, economic and environmental (4 E) analysis. It was found that the NCCP system showed the best performance when all subsystems were running simultaneously. The system could produce 31.67 MW of power, 24.92 MW of cooling capacity, and 29.97 t/h of CO2 capture. The levelized energy cost and the payback period of the NCCP system were 0.071 $/kWh and 7.9 years, respectively. LNG cold energy utilization efficiency, system energy efficiency, and exergy efficiency were 43.20%, 19.08%, and 29.28%, respectively. The environmental profits are validated with the negative carbon index of 29.47 t/h. Moreover, the effects of the LNG pressure, flue gas mass flow rate, and the temperature of the medium temperature shift gas on the NCCP system performances were investigated. The results show that the proposed system is a polygeneration system with the advantages of high efficiency, diversified energy output, fast return on investment, and CO2 capture. It is expected to be an energy conversion technology that could be used for reference in practical applications. (c) 2022 Published by Elsevier Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据