4.7 Article

Reliability of using generic flow conditions to quantify aneurysmal haemodynamics: A comparison against simulations incorporating boundary conditions measured in vivo

期刊

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.cmpb.2022.107034

关键词

Haemodynamics; Intracranial aneurysm; 3-dimensional rotational angiography; (3DRA); AneurysmFlow; Patient-specific boundary conditions; Computational fluid dynamics (CFD)

资金

  1. National Key Research and Development Program of China [2021YFA1000200, 2021YFA1000202, 2020YFC2004400]
  2. National Natural Science Foundation of China [11832003]
  3. IFS, Tohoku University, Japan [J22I075]
  4. Beijing Postdoctoral Research Foundation

向作者/读者索取更多资源

This study compared the simulated haemodynamics of intracranial aneurysms using generic boundary conditions and flow conditions measured in vivo. The results showed that incorporating patient-specific boundary conditions is critical for accurately characterising aneurysmal haemodynamics using computational fluid dynamics (CFD), while different outflow strategies may not introduce significant uncertainties.
Background and objectives: Initiation, growth, and rupture of intracranial aneurysms are believed to be closely related to their local haemodynamic environment. While haemodynamics can be characterised by use of computational fluid dynamics (CFD), its reliability depends heavily upon accurate assumption of the boundary conditions. Herein, we compared the simulated aneurysmal haemodynamics obtained by use of generic boundary conditions against those obtained under flow conditions measured in vivo . Methods: We prospectively recruited 19 patients with intracranial aneurysms requiring 3-dimensional rotational angiography, during which blood pressure at the internal carotid artery was probed by catheter and flowrate measured by a dedicated software tool. Using these flow conditions measured in vivo , we quantified the aneurysmal haemodynamics for each patient by CFD, and then compared the results with those derived from a generic condition reported in the literature, in terms of the time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI), relative residence time (RRT), and percentage of the intra-aneurysmal flow (PIAF). In addition, the effects on aneurysmal haemodynamics of different outflow strategies (splitting method vs . Murray's Law) and simulation schemes (transient vs . steady-state) relative to each flow condition were also assessed. Results: Differences in the simulated TAWSS ( -6.08 +/- 10.64 Pa, p = 0.001), OSI (0.06 +/- 0.13, p = 0.001), and PIAF ( -0.05 +/- 0.20, p = 0.012) between the patient-specific and generic boundary conditions were found to be statistically significant, in contrast to that in the RRT (49 +/- 307 Pa -1, p = 0.062). Out-flow strategies did not yield statistically significant differences in any of the investigated parameters (all p > 0.05); rather, the resulting parameters were found to be in good correlations (all r > 0.71, p < 0.001). Difference between the aneurysmal TAWSS and the WSS derived from cycle-averaged flowrate condition was found to be minor (0.66 +/- 1.36 Pa, p = 0.0 0 0), so was that between PIAFs obtained respectively from the transient and steady-state simulations (0.02 +/- 0.05, p = 0.0 0 0). Conclusions: Incorporating into simulation the patient-specific boundary conditions is critical for CFD to characterise aneurysmal haemodynamics, while outflow strategies may not introduce significant uncer-tainties. Steady-state simulation incorporating the cycle-averaged flow condition may produce unbiased WSS and PIAF compared to the transient analysis. (c) 2022 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据