Influence of the type of electrodes in the assessment of body composition by bioelectrical impedance analysis in the supine position

期刊

CLINICAL NUTRITION
卷 41, 期 11, 页码 2455-2463

出版社

CHURCHILL LIVINGSTONE
DOI: 10.1016/j.clnu.2022.09.008

关键词

Bioelectrical impedance analysis; Body composition; Electrode; Fat-free mass index; Fat mass percentage; Nutritional assessment

资金

  1. Sao Paulo Research Foundation [21554-5]

向作者/读者索取更多资源

This study compared different types of ECG electrodes with a reference electrode in assessing body composition in bedridden patients. The results showed that the use of electrodes with small gel area can affect BIA measurements, especially when phase angle is used as an indicator. Therefore, it is important to specify the type of electrodes and conduct comparative tests to ensure the reliability of measurements in body composition assessment.
Background & aims: The main source of error in body composition assessment of bedridden patients by bioelectrical impedance analysis (BIA) is the electrode inadequacy and placement. As electrocardiogram (ECG) electrodes are often used for BIA measurements, this study aimed to compare three of them with a reference BIA electrode. Methods: BIA was performed sequentially on 24 healthy subjects in the supine position, using 3 different ECG electrodes (3M (R) Red Dot (R) 2330; Ambu (R) BlueSensor 2300; Ambu (R) BlueSensor SU-00-C) and the reference electrode (Bianostic AT (R)) for the BIA device (Nutriguard-M (R), Data Input, Germany). Resistance (R), reactance (Xc), phase angle (PhA), appendicular skeletal muscle index (ASMI), fat-free mass index (FFMI) and fat mass percentage (FM%) obtained with the different electrodes were compared using Bland eAltman plots, repeated measures one-way ANOVA and paired t-test. Patient characteristics potentially involved in BIA measurement differences were assessed using linear regression analysis. Results: The study population consisted of 9 men and 15 women, 33% and 47% of whom were over-weight, respectively. The measured R was within the physiological range for all men (428-561 ohm) and women (472-678 ohm), regardless of the type of electrodes used. Compared to the reference electrode, the 3M (R) Red Dot (R) 2330 and Ambu (R) BlueSensor SU-00-C electrodes gave significantly different Xc and PhA values, but only the Ambu (R) BlueSensor SU-00-C gave significantly different ASMI, FFMI and FM% at 50 kHz, with biases of similar to 0.2 kg/m(2), similar to 0.3 kg/m(2) and thorn1.4%, respectively. The higher the current frequency, the lower was the Xc and PhA measured by the Ambu (R) BlueSensor SU-00-C compared to the reference electrode. These measurement differences seemed mainly due to the too small gel area of the Ambu (R) BlueSensor SU-00-C (154 mm(2)) compared to the reference electrode (1311 mm(2)). Conclusions: The use of electrodes with small gel area affects BIA measurement in the supine position, especially when PhA is used as an indicator of the nutritional status. Therefore, it is essential to specify the type of electrodes and carry out comparative tests before changing consumables for body composition assessment, to ensure BIA measurement reliability in clinical and research settings. (c) 2022 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据