4.3 Article

Combined assessment by transcranial sonography and Sniffin' Sticks test has a similar diagnostic accuracy compared to brain SPECT for Parkinson's disease diagnosis.

期刊

CLINICAL NEUROLOGY AND NEUROSURGERY
卷 220, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.clineuro.2022.107333

关键词

Parkinson; Substantia nigra; Ultrasonography; Smell; Tomography

向作者/读者索取更多资源

This study investigates the accuracy of TCS combined with the SST-16 test for differentiating idiopathic PD patients from healthy controls, and finds that the combination of SST-16 and TCS assessment is accurate for distinguishing PD patients from healthy controls.
Objectives: This study aimed to investigate the accuracy of TCS combined with the Sniffin' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of 99 mTc-TRODAT-1 SPECT (TRODAT). Methods: A cross-sectional study included PD patients diagnosed in accordance with United Kingdom PD Society Brain Bank criteria and a control group of age and sex-matched healthy subjects. All patients were examined by a movement disorder specialist and underwent brain SPECT using TRODAT, TCS examination and SST-16 test. Receiver Operating Characteristic (ROC) curves were used to calculate cut-off points for TCS, striatal TRODAT binding potentials and SST-16. The area under the ROC curve determined the diagnostic accuracy of the method. Results: Twenty patients with PD (13 males and 7 females) and nine healthy subjects were included. Median age of PD onset was 56.5 years with median disease duration of 5 years. A larger substantia nigra (SN) echogenic area was observed in the PD group (p = 0.013). SN echogenic area cut-off point of 0.22 cm2 was obtained from a ROC curve for PD diagnosis. Considering this cut-off point, TCS diagnostic accuracy was estimated at 79.2% for PD diagnosis. The cut-off value of 0.90 for striatal TRODAT binding was associated with 99% diagnostic accuracy for the diagnosis of PD. SST-16 values equal or less than 9 points showed an 85.8% diagnostic accuracy for PD diagnosis. Combination of both SST-16 and TCS improved the diagnostic accuracy to 95% for PD diagnosis. Conclusion: Combined SST-16 and TCS assessment was indicated as accurate for distinguishing PD patients from healthy controls. The diagnostic accuracy of TCS combined with SST-16 for differentiation between idiopathic PD patients and healthy controls is similar to that of SPECT TRODAT.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据