4.8 Article

Laser-induced graphene from paper for non-enzymatic uric acid electrochemical sensing in urine

期刊

CARBON
卷 197, 期 -, 页码 253-263

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.carbon.2022.06.013

关键词

Graphene; Paper-LIG; Uric acid; Human urine; Electrochemical biosensors; Flexible electronics

资金

  1. national funds through the Portuguese Foundation for Science [LA/P/0037/2020, UIDB/50025/2020, UIDP/50025/2020]
  2. national funds through the Portuguese Foundation for Science and Technology/MCTES [LA/P/0037/2020, UIDB/50025/2020, UIDP/50025/2020]
  3. FCT [787410]
  4. BPD [LA/P/0037/2020, UIDB/50025/2020]
  5. National Funds through FCT I.P. under the NANOBIOSENSE [UIDP/50025/2020, SFRH/BD/141525/2018]
  6. ERC AdG [BPD/UI96/5177/2020]
  7. [BPD/UI96/5808/2017]
  8. [PTDC/NAN-MAT/28755/2017]
  9. [POCI-01-0145-FEDER-028755]
  10. Fundação para a Ciência e a Tecnologia [SFRH/BD/141525/2018] Funding Source: FCT

向作者/读者索取更多资源

Laser-induced graphene from paper (paper-LIG) was used for non-enzymatic electrochemical sensing of uric acid in human urine. The paper-LIG electrodes showed high selectivity and sensitivity in detecting uric acid, and have the potential for widespread application in detecting other important biomarkers.
Laser-induced graphene from paper (paper-LIG) was applied in non-enzymatic electrochemical sensing of uric acid (UA) in human urine. Paper-LIG was formed by CO2 laser modification of paper into a 3D graphene arrangement. Kinetic analysis of paper-LIG electrodes returned effective heterogeneous electron transfer standard rate constants of 1.4 x 10(-3) cm s(-1) and 7.8 x 10(-4) cm s(-1) for [Ru(NH3)(6)](2+/3+) and [Fe(CN)(6)](4)(-)(/3)(-) redox probes, respectively. These electrodes were able to detect and quantify uric acid in PBS within the 10-300 mu M range at pH between 5.6 and 7.4. At pH 7.4, a linear response (R-2 = 0.999) from 10 to 250 mu M was achieved, with a limit of detection of 3.97 mu M and a sensitivity of 0.363 mu A cm(-2) mu M-1. Paper-LIG electrodes denoted adequate selectivity in synthetic urine as well as in ascorbic acid (AA) and dopamine (DA)-containing electrolytes. Determination of urinary UA content in human samples returned a concentration of c.a. 1.8-1.9 mM, within the range for healthy individuals. Recoveries of samples spiked with 50 and 100 mu M UA were 100.6% and 95.4%, respectively, with satisfactory reproducibility and stability. These cheap, lightweight, flexible, and eco-friendly paper-LIG biosensors for non-enzymatic quantification of UA in human urine pave the way to widespread application in the detection of other important biomarkers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据