4.4 Article

Geometry-driven coalescence of water droplets in a highly viscous fluid

期刊

CANADIAN JOURNAL OF CHEMICAL ENGINEERING
卷 101, 期 5, 页码 2821-2834

出版社

WILEY
DOI: 10.1002/cjce.24714

关键词

coalescence; constrictor; droplet; laminar flow; VOF

向作者/读者索取更多资源

This study focuses on the numerical investigation of water droplet coalescence in bitumen. Using the Navier-Stokes equations coupled with the volume of fluid model (VOF) and adaptive grids techniques, the behavior of water droplets with different sizes in rapidly converging and diverging microchannels was analyzed. The simulations were validated against experimental data, showing good agreement. The results revealed that the bulk flow velocity in the channel is the main parameter influencing coalescence. Unsteady simulations indicated the existence of a critical flow velocity, above which no coalescence occurs. Additionally, image processing analysis was used to estimate the mean droplet size in different geometries, and it was found that late coalescence in a wider constriction significantly increased the mean size of droplets.
This work is dedicated to numerical studies of the coalescence of water droplets moving in bitumen. The Navier-Stokes equations coupled with the volume of fluid model (VOF) using adaptive grids techniques, available in the commercial computational fluid dynamics (CFD) software Ansys Fluent 20R2, were solved numerically to investigate the behaviour of water droplets with diameters from 1 to 100 mu m moving in rapidly converging and diverging microchannels of different sizes. The model has been validated against 3-D experimental data published in the literature. A good agreement has been demonstrated. The results of simulations revealed that the main parameter influencing coalescence is the bulk flow velocity in the channel. Analysis of unsteady simulations showed the existence of a critical flow velocity, above which no coalescence occurs, corresponding to capillary number Ca < 0.5 for droplets Reynolds number Re < 0.1. Besides, image processing analysis has been used for a mean droplet size estimation in different geometries. A mean size significantly increased due to the late coalescence occurring in a wider constriction.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据