Evaluation of aerosol transmission risk during home quarantine under different operating scenarios: A pilot study

期刊

BUILDING AND ENVIRONMENT
卷 225, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2022.109640

关键词

Aerosol transmission risk; Air conditioning; Natural ventilation; Fans; COVID-19; Home quarantine

资金

  1. National Medical Research Council, Singapore
  2. [COV-ID19RF3-0080]

向作者/读者索取更多资源

This study used tracer gas technique to simulate virus-laden aerosols exhaled by a patient under home quarantine. The results showed that indoor concentration was 4 times higher under air-conditioning settings compared to natural ventilation. Operating an exhaust fan substantially reduced in-room concentration and leakage rate, except for natural ventilation with a ceiling fan. The study recommends natural ventilation instead of air-conditioning and utilizing exhaust fans when using air-conditioning to reduce exposure risk during home quarantine.
SARS-CoV-2 has been recognized to be airborne transmissible. With the large number of reported positive cases in the community, home quarantine is recommended for the infectors who are not severely ill. However, the risks of household aerosol transmission associated with the quarantine room operating methods are under-explored. We used tracer gas technique to simulate the exhaled virus laden aerosols from a patient under home quarantine situation inside a residential testbed. The Sulphur hexafluoride (SF6) concentration was measured both inside and outside the quarantine room under different operating settings including, air-conditioning and natural ventilation, presence of an exhaust fan, and the air movement generated by ceiling or pedestal fan. We calculated the outside-to-inside SF6 concentration to indicate potential exposure of occupants in the same household. Inroom concentration with air-conditioning was 4 times higher than in natural ventilation settings. Exhaust fan operation substantially reduced in-room SF6 concentration and leakage rate in most of the ventilation scenarios, except for natural ventilation setting with ceiling fan. The exception is attributable to the different airflow patterns between ceiling fan (recirculates air vertically) and pedestal fan (moves air horizontally). These airflow variations also led to differences in SF6 concentration at two sampling heights (0.1 m and 1.7 m) and SF6 leakage rates when the quarantine room door was opened momentarily. Use of natural ventilation rather than airconditioning, and operating exhaust fan when using air-conditioning are recommended to lower exposure risk for home quarantine. A more holistic experiment will be conducted to address the limitations reflected in this study.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据