4.8 Article

Target-triggered hybridization chain reaction for ultrasensitive dual-signal miRNA detection

期刊

BIOSENSORS & BIOELECTRONICS
卷 215, 期 -, 页码 -

出版社

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2022.114572

关键词

DNA cascade Reaction; Dual -signal readout; Non -enzymatic; Signal amplification; MOFs derivative

资金

  1. National Natural Science Foundation of China [82061148012, 82027806, 21974019]
  2. National High-tech R D Program [2017YFA0205301]
  3. National Key Research & Development Program of China [BE2019716]
  4. Primary Research & Develop- ment Plan of Jiangsu Province [KYCX20_0142]
  5. Postgraduate Research & Practice Innovation Program of Jiangsu Province

向作者/读者索取更多资源

In this study, a signal amplification sensing system with target-triggered DNA cascade reaction and dual-signal readout technology was designed for ultrasensitive analysis of miRNA. The system utilized highly conductive metal organic frameworks, tetrahedral DNA nanostructure, and non-enzymatic amplification method to improve sensitivity, and showed promising application in complex biological systems.
A signal amplification sensing system with target-triggered DNA cascade reaction combined with dual-signal readout technology was designed for ultrasensitive analysis of miRNA. The highly conductive metal organic frameworks (MOFs) derivative, N-doped carbon dodecahedron (N-PCD) was deposited with gold nanoparticles as the electrode substrate, which could assist the electron transfer between the molecular probe and the electrode surface, and could remarkably enhance electrochemical response. Tetrahedral DNA nanostructure (T4-DNA) with high structural stability and mechanical stiffness was designed to improve the loading capacity and binding efficiency of the target, thus increasing the sensitivity of the system. The non-enzymatic amplification method based on the DNA cascade reaction allows the electrochemical responses from dual signal DNA probes labeled with ferrocene (Fc) and methylene blue (MB), respectively in turn to improve the reliability of detection. Under optimal conditions, the sensor has a linear range of 5-1.0 x 104 fM, and the limit of detection is as low as 1.92 fM and 3.74 fM for Fc and MB labeled probe, respectively. This strategy raises the promising application for the rapid detection of miRNA targets with low abundance in complex biological systems.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据