4.7 Article

Experimental investigation of pool boiling heat transfer on pillar-structured surfaces with different wettability patterns

期刊

APPLIED THERMAL ENGINEERING
卷 215, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2022.118924

关键词

Pool boiling; Structured surface; Wettability pattern; Mixed wetting

资金

  1. National Natural Science Foundation of China [52176093, 51822606]

向作者/读者索取更多资源

In this paper, the pool boiling heat transfer on pillar-structured surfaces with different wettability patterns and channel-to-pillar width ratios was experimentally investigated. The results showed that the effect of wettability patterns on boiling performance was similar to that on plain surfaces, but the differences between hydrophilic and hydrophobic patterns increased with the decrease of the channel-to-pillar width ratio.
In this paper, we experimentally investigate the pool boiling heat transfer on pillar-structured surfaces with different wettability patterns and different values of the channel-to-pillar width ratio. Five types of wettability patterns are compared, i.e., homogeneous hydrophilicity (HPi), homogeneous hydrophobicity (HPo), homoge-neous near-superhydrophilicity (SHPi), a mixed pattern with hydrophilic bottom and hydrophobic pillar top (MPiPo), and another mixed pattern with hydrophobic bottom and hydrophilic pillar top (MPoPi). The effects of homogenous wettability patterns on the boiling performance of pillar-structured surfaces are basically consistent with those on plain surfaces, but the differences between the HPi and HPo patterns are found to be gradually enlarged with the decrease of the channel-to-pillar width ratio. Moreover, compared with the base HPi pattern, the MPoPi mixed pattern leads to a leftward shift of the boiling curve and an upward shift of the heat transfer coefficient (HTC) curve but gives a lower value of the critical heat flux. Such a tendency of the MPoPi mixed pattern is not affected when the channel-to-pillar width ratio is decreased from 2.0 to 0.5. In contrast, the boiling performance of the MPiPo mixed pattern is found to be significantly affected by the channel-to-pillar width ratio as it performs best among the five types of wettability patterns when the channel-to-pillar width ratio gamma > 1, but it deteriorates the boiling heat transfer at high heat fluxes when the ratio gamma is reduced to 0.5.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据