4.4 Article

Development of an equipment for real-time continuous monitoring of alpha and beta radioactivity in river water

期刊

APPLIED RADIATION AND ISOTOPES
卷 187, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.apradiso.2022.110322

关键词

-

资金

  1. Spanish Centro para el Desarrollo Industrial, CDTI, del Ministerio de Ciencia e Innovacion [IDI-20100094]

向作者/读者索取更多资源

This paper describes the optimization of a plastic scintillation microspheres (PSm) detector for continuous monitoring of radioactivity in river water. The detector has high efficiency and low detection limits, making it suitable for water or waste surveillance involving frequent measurements.
Different regulations require the monitoring of radioactivity in the environment (e.g., 2013/51/Euratom, Real Decreto 314/2016) to protect the environment and the population from abnormal radioactivity presence caused by natural reasons or discharges or accidents in nuclear installations. Nowadays, the monitoring of alpha- and beta-emitting radionuclides is performed discontinuously in laboratories due to the difficulties in applying classical techniques to continuous measurements. This limits the number of samples that can be measured per day, produces high costs per analysis, and introduces a significant delay between the moment of contamination and when it is detected. Plastic scintillation microspheres (PSm) represent a new possibility for continuous measurements because water samples can flow through a bed of PSm connected to a pair of photomultipliers (PMTs), allowing continuous monitoring of the activity. This idea is the basis of the Waterrad detector, which can monitor radioactivity at environmental levels in river water. This paper describes the optimization of a detection cell containing PSm, a detection chamber as well as active and passive shielding. In its final set-up, the Waterrad detector presents a background signal of 0.23 (1) cps and detection efficiencies of 1.86(7)middot10(-5) cpsmiddotLmiddotBq(-1) for H-3, 7.4(8)middot10(-3) cpsmiddotLmiddotBq(-1) for Sr-90/Y-90 and 5.5(5)middot10(-3) cpsmiddotLmiddotBq(-1) for Am-241. The detection limits in the optimum window for a counting time of 5 h were 490 Bq/L for H-3, 2.3 Bq/L for Sr-90/Y-90 and 3.0 Bq/L for Am-241. These values indicate that Waterrad can be used as an alarm detector for monitoring radioactivity in water at activity levels similar to those of environmental samples, making it suitable for water or waste surveillance involving a high frequency of measurements.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据