4.7 Article

Dual-signal optical detection of Lead(II) ions (Pb2+) using galloyl group-functionalized polydiacetylene

期刊

ANALYTICA CHIMICA ACTA
卷 1230, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2022.340403

关键词

Polydiacetylene (PDA); Heavy metal(Pb2+); Galloyl group; Colorimetric sensor; Fluorescent sensor; Point-of-care testing (POCT) sensor

资金

  1. Inje University [20180126]

向作者/读者索取更多资源

In this study, a novel Galloyl-PDA sensor was developed for colorimetric and fluorescent detection of Pb2+. The sensor exhibited high sensitivity and specificity, making it suitable for rapid detection of Pb2+ in samples such as tap water, river water, and human serum.
In this study, we developed a novel galloyl group-functionalized polydiacetylene (Galloyl-PDA) sensor for colorimetric and fluorescent detection of Pb2+. Among three types of Galloyl-PDA vesicles prepared by changing the ratio of newly synthesized galloyl group-conjugated 10,12-pentacosadiynoic acid (Galloyl-PCDA) and matrix 10,12-tricosadinoic acid (TCDA), the blue Galloyl-PDA vesicles with 1:9 molar ratio of Galloyl-PCDA:TCDA showed the most dramatic color transitions to red with colorimetric response (CR) value of 46.66 & PLUSMN; 1.373% within 5 min upon addition of 50 mu M Pb2+. However, they didn't exhibit any color change upon interaction with other heavy metals. Since the terminal galloyl moieties of the Galloyl-PDA vesicles could form coordination bonds with Pb2+, the Galloyl-PDA vesicles were stressed and showed obvious blue-to-red chromatic transitions. Besides, because the Galloyl-PDA vesicles exhibited nonfluorescent-to-fluorescent transitions, a linear response in colorimetric and fluorescent signals was observed in the range of 0-10 mu M and 0.025-1 mu M, respectively. From the colorimetric and fluorescent results, the limit of detection (LOD) was determined to be 1.329 mu M and 0.068 mu M, which is 8-fold and 12-fold better sensitivity than those of previously reported methods, respectively. Furthermore, the capability of our PDA sensor for detection of Pb2+ in tap water, river water, and human serum was validated with excellent precision and recovery rates of 97.14-100.0%, 99.05-103.3%, and 100.7-106.7%,respectively. As our PDA dual-signal sensor for Pb2+ is rapid, sensitive, specific, and detectable by the naked eye, this approach holds great promise for application in point-of-care testing (POCT).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据