4.7 Article

An aptasensor for cadmium ions detection based on PEI-MoS2@Au NPs 3D flower-like nanocomposites and Thi-PtPd NPs core-shell sphere

期刊

ANALYTICA CHIMICA ACTA
卷 1232, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.aca.2022.340470

关键词

Cd2+; Electrochemical aptasensor; MoS2 NFs; Nanocomposites; Thionine

资金

  1. National Natural Science Foundation of China [61301037]
  2. Program for Science and Technology Innovation Talents in Universities of Henan Province [20HASTIT002]
  3. Natural Science Foundation of Henan Province of China [212300410338]
  4. Innovative Funds Plan of Henan University of Technology Grant [2021ZKCJ13]
  5. Open Fund from Research Platform of Grain Information Processing Center in Henan University of Technology [KFJJ-2021-106]
  6. Master's Degree Thesis Cultivation Project of Henan University of Technology

向作者/读者索取更多资源

A novel ultrasensitive electrochemical aptasensor using PEI-MoS2 NFs@Au NPs for Cd2+ detection was proposed, showing high sensitivity and promising application prospects.
A novel ultrasensitive electrochemical aptasensor was proposed for quantitative detection of Cd2+. To this end, flower-like polyethyleneimine-functionalized molybdenum disulfide-supported gold nanoparticles (PEI-MoS2 NFs@Au NPs) were used as substrates for the modification of bare gold electrodes (AuE). PEI-MoS2 NFs@Au NPs not only possessed excellent biocompatibility and large specific surface area to enhance the cDNA loading capacity, but also possessed good conductivity to accelerate the electron transfer rate. Furthermore, the preparation of dendritic platinum-palladium nanoparticles (PtPd NPs) can effectively load Cd2+-aptamer. Thionine and aptamers were loaded onto PtPd NPs to construct Thi-PtPd NPs-aptamer signal probes. The signal probes were captured by the cDNA immobilized on the electrode via base-pairing rule, and the signal of Thi was detected by differential pulse voltammetry (DPV). In the presence of Cd2+, aptamer-cDNA unwinded, and the combination of aptamer and Cd2+ caused the signal probes to fall off the electrode and the electrical signal decreases. Under optimal conditions, the proposed aptasensor exhibited a linear relationship between the logarithm of Cd2+ concentration and the current response over a wide range of 1 x 10-3 nM to 1 x 102 nM, with a detection limit of 2.34 x 10-4 nM. At the same time, the aptasensor was used to detect Cd2+ in tap water with satisfactory results. In addition, it has good reproducibility, selectivity and stability, and has broad application prospects in heavy metal analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据