4.1 Article

Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters

期刊

JOURNAL OF GLAUCOMA
卷 25, 期 6, 页码 510-519

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/IJG.0000000000000359

关键词

corneal stiffness; correction; intraocular pressure

资金

  1. Wenzhou Science and Technology Bureau [C20120009-04]
  2. Science Foundation of the Affiliated Eye Hospital of Wenzhou Medical University [YNCX201312, YNCX201405]
  3. National Natural Science Foundation of China [81300807]
  4. National Institute for Health Research (NIHR) Biomedical Research Centre based at Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology
  5. National Institutes of Health Research (NIHR) [II-LS-1010-10007, II-FS-0908-10031] Funding Source: National Institutes of Health Research (NIHR)
  6. National Institute for Health Research [II-FS-0908-10031, HTD 539, II-LS-1010-10007] Funding Source: researchfish

向作者/读者索取更多资源

Purpose: To evaluate the effectiveness of methods to correct intraocular pressure (IOP) measurements obtained using the Goldmann applanation tonometer (GAT), the ocular response analyzer (ORA), and the Corvis ST tonometer (CVS) for the effects of corneal stiffness parameters: central corneal thickness (CCT), corneal curvature (R), and age in a Chinese population. Patients and Methods: Data were collected for 99 eyes of 99 participants. Whereas cornea-corrected IOP was obtained directly from ORA (ORA-IOPcc), cornea correction in GAT and CVS was implemented using multiparameter equations developed earlier. The study also included IOP measurements by the dynamic contour tonometer, which is thought to be less affected by corneal stiffness parameters than other tonometers. Statistical analyses were performed to determine the association of both uncorrected and corrected IOP with the main stiffness parameters: CCT, R, and age. Results: After correction, a significantly decreased association between the GAT (from r = 0.15 to r = -0.02), ORA (from r= 0.24 to r= -0.19), and CVS (from r = 0.47 to r = 0.004) IOP measurements and the CCT was found, to levels below that with the dynamic contour tonometer-IOP (r = 0.11). The IOP measurements made by the 4 tonometers, both uncorrected and corrected, did not correlate with age. The same was true for R except with ORA-IOPcc (r = 0.23). Conclusions: CCT accounted for the majority of variance in IOP, whereas age and R had a much smaller effect. The IOP correction processes studied were successful in reducing reliance of IOP measurements, especially those by GAT and CVS, on CCT in a healthy Chinese population.