3.9 Article

Thermal Hazard Analysis and Chemical Incompatibility Test with Novel Custom High-Pressure Crucibles Made from Commonly Used Metals and Alloys

期刊

ACS CHEMICAL HEALTH & SAFETY
卷 29, 期 5, 页码 441-447

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acs.chas.2c00032

关键词

process safety; DSC; thermal analysis; thermal hazard analysis; compatibility study

资金

  1. University of Notre Dame IncroperaRemick Fund for Excellence
  2. Robert A. Welch Foundation [F1945]
  3. Gold Plating Services Inc. (Layton, UT)

向作者/读者索取更多资源

The assessment of reactive hazards and chemical incompatibilities is crucial in the chemical and pharmaceutical industries for ensuring safe operations. This study presents the construction of custom differential scanning calorimetry high-pressure crucibles using commonly used metals and alloys. These crucibles offer a cost-effective and efficient method for thermal hazard analysis and compatibility tests at elevated temperatures.
The assessment of reactive hazards and chemical incompatibilities is necessary for safe operations in the chemical and pharmaceutical industries. In this investigation, custom differential scanning calorimetry (DSC) high-pressure crucibles made of commonly used metals and alloys have been constructed in-house using a microwelding system containing a jewelry spot-welder and a microscope. They provide an inexpensive and efficient method to perform thermal hazard analysis and compatibility tests at elevated temperatures compared to a DSC with commercial high-pressure crucibles or an accelerating rate calorimeter (ARC). The application of these crucibles is demonstrated with case studies of the thermal hazard analysis of ammonium nitrate (AN) and an ionic liquid: 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([emim][Tf2N]).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.9
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据