Long-term decay of the water pressure in the osmotic tensiometer

出版社

SCIENCE PRESS
DOI: 10.1016/j.jrmge.2022.05.005

关键词

High suction measurement; Osmotic tensiometers; Long-term pressure decay; Polymer leakage; Viscoelasticity of polymers

向作者/读者索取更多资源

In this study, the mechanism of water pressure decay in osmotic tensiometers (OTs) was explored using crosslinked poly(acrylamide-co-acrylic acid) potassium salt (PAM-co-PAAK) as the polymer material. The results showed that the pressure decay of OT was mainly caused by the stress relaxation of the polymer hydrogels, and the standard linear solid (SLS) rheological model was suitable for fitting the decay data. The research also demonstrated that the pressure decay was not due to polymer leakage, as there was no increase in polymer concentration during the decay period.
Matric suction is an important state variable required for the assessment of unsaturated soil properties. Tensiometers are commonly used for direct matric suction measurement but have a limited measuring range up to 90 kPa due to the cavitation problem. Osmotic tensiometer (OT) can improve the measuring range of tensiometers by increasing the osmotic pressure of water to avoid the cavitation. However, the long-term water pressure decay that appeared in OTs caused a gradual decrease in their measuring range. In this study, crosslinked poly(acrylamide-co-acrylic acid) potassium salt (PAM-co-PAAK) was used for the preparation of OTs (five in total) to explore the mechanism of water pressure decay of OTs. The maximum water pressure in the OT versus the volume fraction of polymer filled in the OT was described based on the Flory-Huggins polymer theories and validated using WP4C dewpoint hygrometer. The long-term pressure decay of OT-1, OT-2, and OT-3 was observed for 130 d and constant pressures were found for OT-1 and OT-2, indicating that the pressure decay of OT was mainly caused by the stress relaxation of the polymer hydrogels, and standard linear solid (SLS) rheological model was appropriate to fit the decay data. For OT-1, OT-2 and OT-3, the theoretical osmotic pressure that was calculated based on the mass of retrieved polymer from OTs after 130-d pressure observation was higher than the actual osmotic pressure as observed, indicating that polymer leakage cannot explain the pressure decay of the OT. The ultravioletevisible (UVevisible) spectrophotometry examined the change in polymer concentrations in the water containers of OT-4 and OT-5 and demonstrated that there was no increase in polymer leakage during the period of pressure decay of OT-4 and OT-5. As a result, the pressure decay of OT was not caused by polymer leakage. The results of this research suggested that the viscoelastic properties of polymers should be taken into consideration in further OT development.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据