4.7 Article

Long-term thermal performance analysis of a large-scale water pit thermal energy storage

期刊

JOURNAL OF ENERGY STORAGE
卷 52, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.est.2022.105001

关键词

Water pit heat storage; Seasonal heat storage; Monitoring data analysis; Mathematical model; TRNSYS; Long term; Thermal performance analysis

资金

  1. Danish Energy Agency EUDP project [64020-2036]
  2. EUDP project [64020-2124, EUDP 2021-II]

向作者/读者索取更多资源

This study investigated the long-term thermal performance of a large-scale water pit thermal energy storage system in Dronninglund, Denmark. A modified 2D model was used to accurately predict the thermal performance of the system, which showed high storage efficiency and low thermal loss.
Large-scale water pit thermal energy storage (PTES) promotes solar district heating (SDH) system as one of the most potential renewable applications for carbon neutrality. PTES needs vast investment and operates in a complicated system with numerous components, highlighting the need for a suitable simulation tool for techeconomic and feasibility investigations. This paper experimentally and theoretically investigated the longterm thermal performance of a 60,000 m3 PTES in Dronninglund, Denmark. Five years measurements were analyzed to investigate the development of temperatures, heat flows, and thermal stratification in heat storage. A modified 2D model was proposed to calculate the thermal performance of the large-scale PTES based on the XST model in TRNSYS. The results showed that the developed model predicts well the storage temperatures and the heat flows. For one-year validation, the deviations of annual charged/discharged energy, internal energy content, and annual thermal loss between the model and the measurements were 2.0%/1.8%, 2.8% and 1.3%, respectively. The Dronninglund PTES showed 90.1% storage efficiency in the five-year investigation due to its high storage utilization cycle of 2.16. Even without any insulation on the sidewall and the bottom of the PTES, the average thermal loss from the two parts only accounted for 32.3% of total heat loss. Meanwhile, the soil region needed four years to stabilize. Approx. 24.4% of the heat loss in summer from the sidewall and the bottom is regained by the PTES in winter, when there is a low temperature in the heat storage. The findings of the paper serve as a good reference for designers and practitioners of water pit heat storage.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据