4.6 Article

Thicker Ice Improves the Integrity and Angular Distribution of CDC48A Hexamers on Cryo-EM Grids

期刊

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fmolb.2022.890390

关键词

cryo-electron microscopy; ice thickness; optimization; preferential orientation; grid preparation; particle integrity; oligomer disassembly; single particle analysis

资金

  1. King Abdullah University of Science and Technology (KAUST)
  2. Office of Sponsored Research (OSR) [URF/1/4039-01-01]
  3. Wellcome Trust [URF/1/4080-01-01]
  4. MRC
  5. BBSRC
  6. EPSRC
  7. King Abdullah University of Science and Technology (KAUST) [P2019-0006]
  8. Office of Sponsored Research (OSR) [URF/1/4039-01-01]
  9. Wellcome Trust [URF/1/4080-01-01]
  10. MRC
  11. BBSRC
  12. EPSRC

向作者/读者索取更多资源

This study investigated how to solve the issues of aggregation, dissociation, and particle orientation in sample preparation for cryo-EM analysis of CDC48A. By improving purification methods and selecting optimal ice thickness for grid freezing, high-quality data was obtained under standard laboratory and microscope settings.
Many cryogenic electron microscopy (cryo-EM) single particle analyses are constrained by the sample preparation step upon which aggregation, dissociation, and/or preferential orientation of particles can be introduced. Here, we report how we solved these problems in the case of CDC48A, a hexameric AAA ATPase from Arabidopsis thaliana. CDC48A hexamers are well preserved under negative staining conditions but disassemble during grid freezing using the classical blotting method. Vitrification of grids using the blot-free Chameleon method preserved the integrity of particles but resulted in their strong preferential orientation. We then used a strategy where we improved in parallel the purification of CDC48A and the conditions for cryo-EM data acquisition. Indeed, we noted that images taken from thicker ice presented an even distribution of intact particles with random orientations, but resulted in a lower image resolution. Consequently, in our case, distribution, orientation, image resolution, and the integrity of particles were tightly correlated with ice thickness. By combining the more homogeneous and stable CDC48A hexamers resulting from our improved purification protocol with an iterative search across different ice thicknesses, we identified an intermediate thickness that retained sufficiently high-resolution structural information while maintaining a complete distribution of particle orientations. Our approach may provide a simple, fast, and generally applicable strategy to record data of sufficient quality under standard laboratory and microscope settings. This method may be of particular value when time and resources are limited.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据