4.7 Article

Kinematic and biomechanical responses of the spine to distraction surgery in children with early onset scoliosis: A 3-D finite element analysis

出版社

FRONTIERS MEDIA SA
DOI: 10.3389/fbioe.2022.933341

关键词

kinematic and biomechanical response; law of diminishing return; traditional growth rod

资金

  1. National Natural Science Foundation of China [11972065]
  2. Beijing Natural Science Foundation [L202006]
  3. Defense Industrial Technology Development Program [JCKY2021601B021]

向作者/读者索取更多资源

Periodical and consecutive spinal distraction is an effective treatment for severe early onset scoliosis, but considerations should be given to the impact of distraction distance, force on spinal kinematics, biomechanics, and the choice of fixed segments. Spinal overall imbalance may occur during distraction even under safe force. The law of diminishing return is confirmed by comparing distraction energy consumption in different distances.
Periodical and consecutive distraction is an effective treatment for severe early onset scoliosis (EOS), which enables the spinal coronal and sagittal plane deformity correction. However, the rate of rod fractures and postoperative complications was still high mainly related to the distraction process. Previous studies have primarily investigated the maximum safe distraction force without a rod broken, neglecting the spinal re-imbalance and distraction energy consumption, which is equally vital to evaluate the operative value. This study aimed to reveal the kinematic and biomechanical responses occurring after spinal distraction surgery, which were affected by traditional bilateral fixation. The spinal models (C6-S1) before four distractions were reconstructed based on CT images and the growing rods were applied with the upward displacement load of 0-25 mm at an interval of 5 mm. Relationships between the distraction distance, the distraction force and the thoracic and lumbar Cobb angle were revealed, and the spinal displacement and rotation in three-dimensional directions were measured. The spinal overall imbalance would also happen during the distraction process even under the safe force, which was characterized by unexpected cervical lordosis and lateral displacement. Additionally, the law of diminishing return has been confirmed by comparing the distraction energy consumption in different distraction distances, which suggests that more attention paid to the spinal kinematic and biomechanical changes is better than to the distraction force. Notably, the selection of fixed segments significantly impacts the distraction force at the same distraction distance. Accordingly, some results could provide a better understanding of spinal distraction surgery.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据