4.4 Article

Biomechanical Evaluation of Spinal Column after Percutaneous Cement Discoplasty: A Finite Element Analysis

期刊

ORTHOPAEDIC SURGERY
卷 14, 期 8, 页码 1853-1863

出版社

WILEY
DOI: 10.1111/os.13314

关键词

Biomechanical; Bone cement; Finite element analysis; Lumbar spinal stenosis; Percutaneous cement discoplasty; PMMA

资金

  1. National Natural Science Foundation of China [82072491, 31900967]
  2. Natural Science Foundation of Tianjin [20JCYBJC00820, 19JCQNJC09300]
  3. Science and technology project of Tianjin Health Commission [KJ20211]

向作者/读者索取更多资源

Comparative analysis of the biomechanical properties of percutaneous cement discoplasty (PCD) in the spinal column revealed that fusion of bone cement and endplate can increase the stability of implants and reduce the risk of subsidence and dislocation.
Objective To compare the biomechanical properties of percutaneous cement discoplasty (PCD) in the spinal column between different implant-endplate friction. Methods A validated L3-Scarumfinite element (FE) model was modified for simulation. In the PCD model, the L4/5 level was modified based on model 1 (M1) and model 2 (M2). In M1, the interaction between bone cement and endplate was defined as face-to-face contact with a friction coefficient of 0.3; in M2, the contact was defined as a Tie constraint. 7.5 N m moments of four physiological motions and axial load of 15, 100 and 400 N preload were imposed at the top of L3. The range of motion (ROM) and interface stress analysis of endplates, annulus fibrosus and bone cement of the operated level were calculated for comparisons among the three models. Results The ROM of M1 and M2 increased when compared with the intact model during flexion (FL) (17.5% vs 10.0%), extension (EX) (8.8% vs -8.8%), left bending (LB) (19.0% vs -17.2%) and left axial rotation (LR) (34.6% vs -3.8%). The stress of annulus fibrosus in M1 and M2 decreased in FL (-48.4% vs -57.5%), EX (-25.7% vs -14.7%), LB (-47.5% vs -52.4%), LR (-61.4% vs -68.7%) and axis loading of 100 N (-41.5% vs -15.3%), and 400 N (-27.9% vs -27.3%). The stress of upper endplate of M1 and M2 increased in FL (24.6% vs 24.7%), LB (82.2% vs 89.5%), LR (119% vs 62.4%) and axis loading of 100 N (64.6% vs 45.5%), and 400 N (58.2% vs 24.3%), but was similar in EX (2.9% vs 0.3%). The stress of lower endplate of M1 and M2 increased in FL (170.9% vs 175.0%), EX (180.8% vs 207.7%), LB (302.6% vs 274.7%), LR (332.4% vs 132.8%) and axis loading of 100 N (350.7% vs 168.6%), and 400 N (165.2% vs 106.7%). Conclusion Percutaneous cement discoplasty procedure could make effect on the mobility or stiffness. The fusion of bone cement and endplate might have more biomechanical advantages, including of the decreasing rate of implant subsidence and dislocation, and the increase spine stability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。